4
4
4-85
4-85
Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit
Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit
Caution : Caution during ITB unit storage.
Be sure to store first ITB unit in the host machine,
otherwise it might scratch the intermediate
transfer belt. Be sure to fix the ITB unit by the ITB
positioning plate and return the ITB release lever
first before fully pushing the fixing feed unit to the
host machine.
5) While pushing the 2 leaf springs, move the fixing feed unit to the front side and release the slide rail lock.
6) Hold the fixing feed unit lever and ITB unit lever, and pull out the fixing feed unit and ITB unit to the each position where they are locked.
Fixing feed unit
ITB unit
Lever of ITB unit
Lever of Fixing feed unit
Leaf spring
Leaf spring
F-4-113