8
8
8-431
8-431
Service Mode > SORTER > ADJUST
Service Mode > SORTER > ADJUST
SORTER> ADJUST
GLU-AMT3
Glue amount adj3: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 3.5 to 6.4 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
GLU-AMT4
Glue amount adj4: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 6.5 to 11.4 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
GLU-AMT5
Glue amount adj5: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 11.5 to 22.4 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
SORTER> ADJUST
GLU-AMT6
Glue amount adj6: trimmer
Lv.1 Details
To adjust the glue application amount on the return way at the glue
thick application by changing the space between the paper stack
(thickness 22.5 to 25 mm) and the scraper plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When the glue application amount is not appropriate on the paper
stack
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
GLU-MOVE
Adj of glue vat shift amount: trimmer
Lv.1 Details
To adjust the shift amount of glue vat at glue application on the
trimmer.
Display/adj/set range
-80 to 80
Default value
0
GLU-TEMP
Set of glue temperature control: trimmer
Lv.1 Details
[Not used]
To set the control temperature of glue on the trimmer.
Display/adj/set range
-145 to 165
Default value
153
GLUAMT1C
Coated paper glue amount adj1: trimmer
Lv.1 Details
To adjust the glue application amount on the coated paper on the
return way at the glue thick application by changing the space
between the paper stack (thickness 0 to 1.4 mm) and the scraper
plate.
As the value is changed by 1, the space gets wider/narrower by
0.05 mm (as the space is widened, the glue application amount is
increased).
+: space is widened (application amount increased)
-: space is narrowed (application amount is decreased)
Use case
When glue peeling occurs with normal glue application amount on
the coated inner sheet
Display/adj/set range
-20 to 20
Unit
0.05 mm
Default value
0
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...