2
2
2-81
2-81
Technology > Fixing System > Servicing work > Action for parts replacement
Technology > Fixing System > Servicing work > Action for parts replacement
Servicing work
■
Periodically Replaced Parts
No.
Part name
Part No. Q'ty Interval
Remarks
1 Fixing roller main thermistor
FK2-6479
1
1000K
2 Fixing roller sub thermistor
FK2-6478
1
1000K
3 Fixing roller thermo switch
FM3-2781
1
1000K
4 Pressure roller main thermistor
FK2-6479
1
1000K
5 Pressure roller sub thermistor
FM3-2874
1
1000K
6 Pressure roller thermo switch
FK2-6478
1
1000K
7 Externl heat roller thermistor
FK2-7282
1
1000K
8 External heat roller thermo switch 1 FM3-2778
1
1000K
9 External heat roller thermo switch 2 FM3-2779
1
1000K
■
Durables
No.
Part name
Part No. Q'ty Interval
Remarks
1 Fixing web
FC7-8910
1
1000K
2 Fixing web roller
FC8-9709
1
5000K
3 Fixing roller
FL2-7345
1
1000K TYPE A
FL2-7437
1
1000K TYPE B
4 Fixing roller insulate bush
FL2-7395
1
1000K
5 Fixing roller bearing
XG9-0421
1
1000K
6 Pressure roller
FL2-7650
1
1000K TYPE A
FL2-7438
1
1000K TYPE B
8 Pressure roller insulate bush
FC8-9693
1
1000K
7 Pressure roller bearing
XG9-0477
1
1000K
9 Refresh roller
FM3-2876
1
1000K
10 External heat roller unit
FM3-2785
1
1000K
Operator replace the unit.
Service engineers replace the
external heat roller, cleaning
roller, insulate bush and bearing.
11 External heat roller
FC9-7217
1
1000K
12 External heat cleaning roller
FM3-1647
1
1000K
13 External heat insulate bush
FC5-2582
1
1000K
14 External heat bearing
XG9-0750
1
1000K
15 Fixing roller separation claw
FM3-2878
1000K
16 Pressure roller separation claw
unit
FM3-2776
1000K
Operator replace the unit.
Service engineers replace the
lower separation claw.
17 Pressure roller separation claw FM3-2769
1
1000K
T-2-76
T-2-77
■
Periodial Servicing
No.
Parts Name
Task
Interval
Remarks
1 Refresh roller
Cleaning
500K
Durable. Interval is 1000K sheets.
2 Fixing inlet guide
Cleaning
500K
3 Fixing roller separation claw
Cleaning
500K
Durable. Interval is 1000K sheets.
4 Pressure roller separation claw
Cleaning
500K
Durable. Interval is 1000K sheets.
■
Action for parts replacement
To prevent the abnormal noise, apply the grease (molykote) onto the inner surface and outer
surface of the bushing.
T-2-78
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...