Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
COPIER> ADJUST> CCD
MTF2-S12
MTF value setting 12: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M10
MTF value setting 10: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M11
MTF value setting 11: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
COPIER> ADJUST> CCD
MTF-M12
MTF value setting 12: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S10
MTF value setting 10: sub scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S11
MTF value setting 11: sub scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...