Technology > Pickup / Feed System > Pre-fixing feed Area > Pre-fixing feeding assembly lifter control
Technology > Pickup / Feed System > Pre-fixing feed Area > Pre-fixing feeding assembly lifter control
Pre-fixing feed Area
■
Pre-fixing feeding assembly lifter control
Pre-fixing feeding assembly performs the lifting, and the path is changed according to the
paper size.
Paper with feed direction less than 227.3 mm : upper path
Paper 227.3 mm or more with feed direction : lower path
Upper path
M29
PS63
ON
Registration/duplexing driver PCB
PCB4
F-2-174
Lower path
PS63
M29
Registration/duplexing driver PCB
PCB4
MEMO :
Since the loop control is executed for the paper 227.3 mm or more with feed direction,
lower path is used to enable the paper loop.
Since the loop control is not executed for the paper with feed direction less than 227.3
mm, thus, the upper path, the supreme straight path form is used for the feeding.