Service Mode > COPIER > DISPLAY (Status Display Mode) > DPOT
Service Mode > COPIER > DISPLAY (Status Display Mode) > DPOT
COPIER> DISPLAY> DPOT
EPC-VL1
Dspl of potential VL1 at potential cntrl
Lv.1 Details
Displaying light area potential VL1 at the time of laser output (50H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL2, EPC-VL3, EPC-VL4
EPC-VL2
Dspl of potential VL2 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (90H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL3, EPC-VL4
EPC-VL3
Dspl of potential VL3 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (C0H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL2, EPC-VL4
COPIER> DISPLAY> DPOT
EPC-VL4
Dspl of potential VL4 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (F0H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL2, EPC-VL3
T-8-9
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...