7
7
7-76
7-76
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E5B0 8010 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
After the glue pile setting temperature rise through the internal
temperature thermistor (S105), the setting temperature is not
getting /- 5 degree C. (not detected within 100 sec
after warm up is completed).
Measures 1. Replace the heater (HTR1).
2. Replace the internal temperature thermistor (S105).
3. Replace the slave controller PCB.
E5B0 8011
61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
After the glue pile setting temperature drop through
the internal temperature thermistor (S105), the setting
temperature is not getting /- 5 degree C. (not detected
within 100 sec after warm up is completed).
Measures 1. Replace the heater (HTR1).
2. Replace the internal temperature thermistor (S105).
3. Replace the slave controller PCB.
E5B0 8012 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
Warm up is not finished within 500 sec after the temperature
adjustment starts.
Measures 1. Replace the heater (HTR1).
2. Replace the slave controller PCB.
E5B0 8013 61
Title
Error in the inside temperature of the perfect binder.
Description
of detection
Under 0 degree C in the inside temperature thermistor (S105)
is detected.
Measures 1. Out-of-specification environment.
2. Replace the slave controller PCB.
E5B2 8001 61
Title
Error in the glue pile level detection of the perfect binder.
Description
of detection
The level detection thermistor (S58) detected that the fluid
level position is lower than lower limit 4 times in a row during
glue supply.
Measures 1. Check the movement of the glue supply system.
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
E5B2 8002 61
Title
Error in the glue pile level detection of the perfect binder.
Description
of detection
Gluing is not performed, hence even the glue is supplied in
the amount set when the fluid level position is higher than
lower limit position, the fluid level detection position doesn’t
become higher than upper limit position by the level detection
thermistor (S58).
Measures 1. Check the movement of the glue supply system.
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
Code
Detail
Code
Location
Item
Description
E5B2 8003 61
Title
Error in the glue pile level detection of the perfect binder.
Description
of detection
Glue supply is not performed, even gluing is performed in the
amount set, the fluid detection position doesn’t become lower
than upper limit position by the level detection thermistor (S58)
.
Measures 1. Check the movement of the gluing.
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
E5B2 8004 61
Title
Error in the glue pile level detection of the perfect binder.
Description
of detection
Error in the adjustment value of the level detection thermistor
(S58) is detected.
Measures 1. Replace the remain detection thermistor (S58).
2. Replace the slave controller PCB.
E5B4 8001 51
Title
DA error in side registration shift sensor (S1) of the stacker
Description
of detection
When adjusting sensor, AD entry for side registration shift
sensor (S1) failed to be within the adjustment range although
making DA output larger than the upper limit.
Measures 1. Check the connector of the side registration shift sensor
(S1), and replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8001 52
Title
DA error in side registration shift sensor (S1) of the 2nd
stacker
Description
of detection
When adjusting sensor, AD entry for side registration shift
sensor (S1) failed to be within the adjustment range although
making DA output larger than the upper limit.
Measures 1. Check the connector of the side registration shift sensor
(S1), and replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8001 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the timing sensor (S5) changed
up to the upper limit value, the A/D input limit can’t get within
the set range.
Measures 1. Clean the timing sensor (S5), and replace the sensor if
necessary.
2. Replace the master controller PCB.
E5B4 8002 51
Title
DA error in gripper HP sensor (S15) of the stacker
Description
of detection
When adjusting sensor, AD entry for gripper HP sensor (S15)
failed to be within the adjustment range although making DA
output larger than the upper limit.
Measures 1. Check the connector of the gripper HP sensor (S15), and
replace the sensor if necessary.
2. Replace the master controller PCB.
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...