2
2
2-192
2-192
Technology > eM Controller-E1 > Troubleshooting guide
Technology > eM Controller-E1 > Troubleshooting guide
No.
Error text
Error description
Cause
Remedy
22 Proxy address
resolution error
Proxy address
resolution error
Cannot connect to proxy
server.
Check that the proxy
server name is correct. If
the proxy server name is
correct, check the DNS
connection, as per the
troubleshooting initial
procedures.
23 Server certificate
verify error
Server certificate
verify (URL Check
error) error
The server certificate
verification error
Check that Service mode
> Function > Install
> RGW-ADR can be
https://a01.ugwdevice.
net/ugw/agentif010.
24 Server address
resolution error
UGW server
address resolution
error
Server address name
resolution has failed.
Check that Service mode
> Function > Install
> RGW-ADR can be
https://a01.ugwdevice.
net/ugw/agentif010.
T-2-105