Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
COPIER > OPTION > USER
DK4-ASST
Air heater setting of POD lower deck
Lv.1 Details
Set the condition (media/environment) to turn on the paper
separation air heater at the POD lower deck.
When the media is switched from non-coated paper to coated paper,
paper pickup operation does not start until the temperature of the
paper separation air heater reaches the specified temperature.
To shorten the wait time, make a setting of “Not dependent on the
media”.
When the use environment is near the threshold for turning ON/
OFF the heater, switching occurs frequently, which increases the
wait time. To shorten the wait time, make a setting of turning on the
heater constantly.
Use case
When it is requested to shorten the wait time
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Caution
• To make a setting of “Not dependent on the media”, be sure to
receive approval from the user in advance after explaining that
there is a possibility that transfer performance for non-coated
paper may decrease.
• To make a setting of turning on the heater constantly, be sure to
receive approval from the user in advance after explaining that
there is a possibility that transfer performance may decrease when
humidity decreases.
Display/adj/set range
0 to 2
0: Dependent on the media and environment condition
1: Dependent on the environment condition (Not dependent on the
media)
2: Turning on the heater constantly (Not dependent on environment/
media)
Default value
0
Related service mode
COPIER> OPTION> USER> DK1-ASST to DK3-ASST, DK5-ASST
to DK10ASST
COPIER > OPTION > USER
DK5-ASST
Air heater setting of POD2 upper deck
Lv.1 Details
Set the condition (media/environment) to turn on the paper
separation air heater at the tandem POD upper deck.
When the media is switched from non-coated paper to coated paper,
paper pickup operation does not start until the temperature of the
paper separation air heater reaches the specified temperature.
To shorten the wait time, make a setting of “Not dependent on the
media”.
When the use environment is near the threshold for turning ON/
OFF the heater, switching occurs frequently, which increases the
wait time. To shorten the wait time, make a setting of turning on the
heater constantly.
Use case
When it is requested to shorten the wait time
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Caution
• To make a setting of “Not dependent on the media”, be sure to
receive approval from the user in advance after explaining that
there is a possibility that transfer performance for non-coated
paper may decrease.
• To make a setting of turning on the heater constantly, be sure to
receive approval from the user in advance after explaining that
there is a possibility that transfer performance may decrease when
humidity decreases.
Display/adj/set range
0 to 2
0: Dependent on the media and environment condition
1: Dependent on the environment condition (Not dependent on the
media)
2: Turning on the heater constantly (Not dependent on environment/
media)
Default value
0
Related service mode
COPIER> OPTION> USER> DK1-ASST to DK4-ASST, DK6-ASST
to DK10ASST
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...