102
KEY SWITCHES
Key-switch Area Assignment
P111E 1-2E
K/S 1 & 2 assigned to Areas A or B -
1 = Assigned to Area “A”
Page 66
(1 = K/S # 1) (Default K/S # 1 = 1)
2 = Assigned to Area “B”
(2 = K/S # 2) (Default K/S # 2 = 2)
Key-switch Access & Operational Options
P112E 1-2E
K/S 1 & 2 Access & Operational Options
1 = K/S can Arm Area
Page 67
(1 = K/S # 1)
(Default = All Off)
2 = K/S can arm Stay Mode
(2 = K/S # 2)
3 = K/S can Disarm Area
4 = K/S can disarm Stay Mode
5 = K/S has Security Guard Options
6 = K/S will Arm Latchkey Mode
7 = Key-switch is N/O (If turned off the K/S is N/C)
8 = Key-switch is Momentary (If turned off the K/S is Latching)
ZONES
Programming Zones to Areas
P121E 1-16E
Assigning Zones to Areas A or B
1 = Assigned to Area “A”
Page 67
(Default = 1)
2 = Assigned to Area “B”
Programming Zone Options A
P122E 1-16E
Programming Zone Options A
1 = Zone is Active
Page 67
(Default Zone 1-4 = 1,6,7,8)
2 = Zone is N/O (Off = N/C)
(Default Zone 5-8 = 1,7,8)
3 = Spare
(Default Zone 9-16 = 7,8)
4 = Keypad Zone
5 = Zone is a Radio Zone
6 = Zone is a Stay Mode Zone
7 = Zone can be Manually Bypassed
8 = Zone can be Auto-Bypassed
Programming Zone Options B
P123E 1-16E
Programming Zone Options B
1 = Zone is a Handover Zone
Page 68
(Default Zone 2, 3 = 1
2 = Zone is a Two Trigger Zone
3 = Zone is a 24 Hour Zone
4 = Zone is a 24 Hour Auto-reset Zone
5 = Zone is a 24 Hour Fire Zone
6 = Spare
7 = Zone is a Chime Zone
8 = Zone is a Permanent Chime Zone
Programming Zone Options C
P124E 1-16E
Programming Zone Options C
1 = Can Arm if Zone is not Ready
Page 69
(Default = 2)
2 = Will Send Multiple Reports via Dialler
3 = Sensor-Watch Zone
4 = Zone is on Soak Test
5 = Zone will report to Area B Account Number
6 = Zone will Not Report 24 hour Alarms via Dialler
7 = Pulse Output on Kiss-off Following an alarm
8 = Exit Terminator
Programming Zone EOL (End-of-line) Options
P125E 1-8E
Programming Zone EOL Options
0 = Short Circuit
Page 70
(Default = 3)
1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k
12 = 2k2 / 4k7
13 = 3k3 / 6k8
14 = 2k2 / 4k7 / 8k2
15 = 4k7 / 8k2
Programming Zone Response
P126E 1-8E
Programming Zone Response
1 to 8 Vibration mode
Page 70
(Default = 15)
(Zone EOL-P125E, for Vibration Mode MUST be type 3 only )
1 = highest and 8 is lowest sensitivity level.