91
WALK TEST MODE
WALK-TEST MODE
- P200E 6E
This address is used to start walk-test mode while in installer or client program mode. By pressing P200E6E at the
keypad, the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is active. If a siren is connected to
an Output and that output has option 1 turned on at location P36E the siren will give a 1 second beep every time a zone
is triggered while walk-test mode is active. By walking past all of the detectors connected to the system and activating
them, the associated zone will latch up at the keypad to allow verification that all zones are working properly. By
pressing the <Program> or <Enter> button, walk-test mode will be terminated and the panel will leave program mode.
The results of the walk-test will be saved in the memory event buffer and can be viewed by accessing memory display
mode to verify which detectors were triggered during walk-test mode. If Output 1 or 2 are used for the Audible walk-test
indication and a horn speaker is connected to the output (see P37E1 or 2E option 1), the siren on the output will give a
single tone for the chirp instead of the swept tone used for alarms.
WRITE TO EEPROM (DTU) BOARD
WRITE to EEPROM[DTU] BOARD
- P200E 7E
This location is used to copy the panels program configuration to an external EEPROM memory card (DTU-Data Transfer
Unit) which can be plugged into the expansion socket on the control board. The write protect link on the DTU board
must be ON for the data to be transferred.
READ FROM EEPROM (DTU) BOARD
READ from EEPROM[DTU] BOARD
- P200E 8E
This location is used to return the panels program configuration from an external EEPROM memory card (DTU-Data
Transfer Unit) which can be plugged into the expansion socket on the control board.
DEFAULT CODES & TELEPHONE NUMBERS
DEFAULT CODES & TELEPHONE NUMBER
- P200E 9E
This location is used to return the panels User and Installer Codes plus the Telephone Numbers & Account Codes to the
default settings.
Event
Description
Program
Number
Alarm
Restore
Bypass
Un-
Bypass
Trouble
Trouble
Restore
Near
Alarm
Verified
Alarm
Burglary
1
BA
BH
BB
BU
BT
BJ
BA
BV
Un-typed Alarm
2
UA
UH
UB
UU
UT
UJ
-
-
Hold-up
3
HA
HH
HB
HU
HT
HJ
-
-
Fire
4
FA
FH
FB
FU
FT
FJ
FA
FM
Medical
5
MA
MH
MB
MU
MT
MJ
-
-
Panic
6
PA
PH
PB
PU
PT
PJ
-
-
Emergency
7
QA
QH
QB
QU
QT
QJ
-
-
Gas
8
GA
GH
GB
GU
GT
GJ
-
-
Sprinkler
9
SA
SH
SB
SU
ST
SJ
-
-
Water
10
WA
WH
WB
WU
WT
WJ
-
-
Heat
11
KA
KH
KB
KU
KT
KJ
-
-
Freeze
12
ZA
ZH
ZB
ZU
ZT
ZJ
-
-
Equipment
13
IA
IR
-
-
-
-
-
-
CHART FOR THE PROGRAMMABLE SIA EVENT CODES
Equip. Tamper
14
TA
TH
TB
TU
TT
TJ
-
-