73
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
If a zone is programmed as a Chime zone (P123E7E) and it activates, the zone can trigger selected Outputs for local alarm
signalling. The output will operate for the Chime to Output time at location P41E. The zone must clear before the output
can be activated again.
ZONE TAMPER ALARMS to OUTPUT
ZONE TAMPER ALARMS to OUTPUT -
P132E 1-16E
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
If a hardwired zone is programmed to allow tamper monitoring (P125E types 12,13 & 14), or the zone is a radio detector
with tamper, the zone tamper can trigger selected Outputs for local alarm signalling.
ARMED ZONE ALARM BEEPS TO KEYPAD
ARMED ZONE ALARM BEEPS TO KEYPAD -
P134E 1-16E
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8
If an Area is Armed and a zone assigned to that Area activates, the zone can sound the buzzer at selected keypads for local
alarm signalling. This location assigns zone alarm beep to a keypad for alarms that occur when in the Full Armed State.
STAY MODE ZONE ALARM BEEPS TO KEYPAD
STAY MODE ZONE ALARM BEEPS TO KEYPAD -
P135E 1-16E
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8
If an Area is Stay Mode Armed and a zone assigned to that Area activates, the zone can sound the buzzer at selected
keypads for local alarm signalling. This location assigns zone alarm beep to a keypad for alarms that occur when in Stay
Mode is Armed.
24 HOUR ZONE ALARM BEEPS TO KEYPAD
24 HOUR ZONE ALARM BEEPS TO KEYPAD -
P136E 1-16E
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8
If a zone is programmed as a 24 Hour type and it activates, the zone can sound the buzzer at selected keypads for local
alarm signalling. If the zone is a standard 24 hour type (P123E3E) or Fire type (P1235E) the keypad buzzer will sound until
reset by a User but if it is an Auto-reset type (P123E4E) the keypad buzzer will reset when the input clears.
CHIME ZONE ALARM BEEPS TO KEYPAD
CHIME ZONE ALARM BEEPS TO KEYPAD -
P137E 1-16E
Option 1 - Keypad 1
Option 5 - Keypad 5
Option 2 - Keypad 2
Option 6 - Keypad 6
Option 3 - Keypad 3
Option 7 - Keypad 7
Option 4 - Keypad 4
Option 8 - Keypad 8