60
Option 8
Turn Off Keypad LCD & Keypad Backlighting on Mains Fail
- This option allows the backlighting on an LCD
on a keypad (both the keypad buttons and the LCD module backlighting) to be turned off when there is a
Mains Failure. It is normally used to cut the power consumed by the keypad during a power failure. The LCD
backlighting will turn off within 90 seconds of the mains failing. If a button is pressed at the keypad the
backlighting will turn back on again. Following 90 seconds of no keypad activity the backlighting will turn
off. The LCD backlighting will return to the normal state when Mains is restored.
KEYPAD <ARM> BUTTON AREA ASSIGNMENT
KEYPAD <ARM> BUTTON AREA ASSIGNMENT
- P74E 1-8E
Option 1 - Area “A”
Option 2 - Area “B”
Option 1
Area “A”
- This option assigns the keypad <ARM> button to Area A. If a keypad <ARM> button is assigned
to only Area A it can only Arm or Disarm that area.
Option 2
Area “B”
- This option assigns the keypad <ARM> button to Area B. If a keypad <ARM> button is assigned
to only Area B it can only Arm or Disarm that area.
KEYPAD <ARM> BUTTON AREA OPTIONS
KEYPAD <ARM> BUTTON AREA OPTIONS
- P75E 1-8E
Option 1 - <ARM> button can Arm
Option 2 - <ARM> button can Arm Stay Mode
Option 3 - <ARM> button can Disarm at All Times
Option 4 - <ARM> button can Disarm Stay Mode at All Times
Option 5 - <ARM> button can Reset Alarms
Option 6 - <ARM> button can Arm Latchkey Mode
Option 7 - <ARM> button can Disarm During Exit Delay
Option 8 - <ARM> button can Disarm Stay Mode During Exit Delay
Option 1
<ARM> button can Arm
- This option enables single button Arming using the <ARM> button. For single
button operation to work options 1 & 3 must be off at location P46E.
Option 2
<ARM> button can Arm Stay Mode
- This option enables single button Arming of Stay Mode using the
<ARM> button. For single button operation to work options 1 & 3 must be off at location P46E.
(NOTE: Following arming of Stay Mode, if the <ENTER> button is pressed, all entry & exit delays will be
reset to zero for that armed period).
Option 3
<ARM> button can Disarm at All Times
- This option enables single button Disarming using the <ARM>
button. For single button disarm operation to work options 1 & 3 must be off at location P46E
Option 4
<ARM> button can Disarm Stay Mode at All Times
- This option enables single button Disarming of Stay
Mode using the <ARM> button. For single button disarm operation to work options 1 & 3 must be off at
location P46E
Option 5
<ARM> button can Reset Alarms
- If this option is On, Pressing the <ARM> button (provided Option 3 is
also On) will reset an alarm condition without having to enter a user code.
Option 6
<ARM> button can Arm Latchkey Mode
- This option enables single button Arming of the alarm in
Latchkey report mode using the <ARM> button. For single button disarm operation to work options 1 & 3
must be off at location P45E. When Latchkey Mode is set on Arming, any code without the Latchkey option
(P4E Option 6) used to Disarm the Alarm will cause a Disarm report to be sent via the dialler.
Option 7
<ARM> button can Disarm During Exit Delay
- This option allows single button Disarming using the
<ARM> button provided the Armed Mode exit delay is active. If the exit delay has expired the <ARM>
button cannot be used to disarm the alarm. For single button disarm operation to work options 1 & 3 must
be off at location P46E
Option 8
<ARM> button can Disarm Stay Mode During Exit Delay
- This option allows single button Disarming of
Stay Mode using the <ARM> button provided the Stay Mode exit delay is active. If the Stay Mode exit delay
has expired the <ARM> button cannot be used to disarm Stay Mode. For single button disarm operation to
work options 1 & 3 must be off at location P46E