116
Contact ID Reporting Code Summary
In addition to the programmable Contact ID Event Code assignments defined at P157E, P158E, P159E, P175E (10E-12E) there are a
number of fixed event codes. The programmable and fixed event codes are all listed in the table below. Associated with the fixed and
programmable event codes, there are a number of extension codes, that are also listed below. The list of extension codes is for your
reference only and can not be changed in programming.
Event Type
Event Code
Extension
Comment
System Tamper
137
000
Panel & Sat Tamper etc
Zone Alarm (wired or wireless)
130
001 to 016
Alarm on Zone 1-16
Zone Tamper - Low (short circuit)
383
001 to 008
Zone Input 1-8 short circuit
Zone Tamper - High (open circuit)
383
009 to 016
Zone Input 1-8 open circuit
Zone Tamper - Radio Zone
383
001 to 016
Radio Zone 1-16
Zone Near Alarm
138
001 to 016
Zone Input 1-16
Zone Confirmed Alarm
139
001 to 016
Zone Input 1-16
Radio PIR / Reed Switch Battery Low
384
001 to 016
Radio Zone 1-16
Radio PIR Supervised Alarm
381
001 to 016
Supervised Radio Zone 1-16
Sensor-watch Alarm
391
001 to 016
Zone 1-16
Zone Excludes
570
001 to 016
Exclude Zone 1-16
Keypad Panic (or 1&3)
120
001 to 008
Panic at keypad #1-8
Radio-Key Panic
120
021 to 100
Panic by Radio User # 21-100
Keypad Fire (4&6)
110
001 to 008
Fire Alarm at keypad #1-8
Keypad Medical (7&9)
100
001 to 008
Medical Alarm at keypad #1-8
Keypad Tamper Switch Alarm
137
101 to 108
Keypad 1-8 Tamper Switch Activated
Wrong Code Alarm
461
001 to 008
4 Incorrect code entries at KP # 1-8
Arm/Disarm by "ARM key (Quick Arm)
408
000
Arm/Disarm by single button
Arm/Disarm by user code
401
001 to 100
Arm/Disarm by User #1-100
Arm/Disarm by Radio-key
400
021 to 100
Arm/Disarm by Radio User #21-100
Arm/Disarm by Key-switch
409
000
Key-switch # 1 Arm/Disarm
409
001
Key-switch # 2 Arm/Disarm
Arm/Disarm by DTMF or Up/Download
407
000
Remote Arm/Disarm
Arm/Disarm by Time-Zone
403
000
Time-Zone Arm/Disarm
Latchkey Disarm
642
001 to 100
Latchkey User Disarm
Fail to Arm on Time-Zone
455
000
Auto Arm fail
Delinquency Alarm
454
000
System not Armed within # days
Stay Mode Arm/Disarm (part set)
441
000
Arm by “Stay” Button
Stay Mode Arm/Disarm (part set)
441
001 to 100
Stay Mode Arm by User # 1-100
Stay Mode Arm/Disarm by Key-switch
442
000
Stay Mode Arm by Key-switch # 1
Stay Mode Arm/Disarm by Key-switch
442
001
Stay Mode Arm by Key-switch # 2
Mains Fail
301
000
Mains (AC) fail
System Battery Low
302
000
Control Panel Battery low
Checksum Fail (Corrupt EEPROM Data)
303
001-008
Checksum block error
Fuse Fail
312
000
Fuse 1 or 2 Fail
Radio-key Battery Low
384
021 to 100
Radio-key User #21-100 low batt.
Radio-PIR / Reed Switch Battery Low
384
001 to 016
Radio Zone 1-16
Automatic TEST Calls
602
000
24 hour test
Manual TEST Calls
601
000
User generated Test Call
Phone Line Failure
351
000
Reported when line is restored
Duress Alarm
121
001 to 008
Duress at Keypad #1-8
Program Mode Entry
627
000
Program Mode entered
Program Mode Exit
628
000
Program Mode exited
Output 1 or 2 Tamper
323
001 or 002
O/P 1 or 2 wires cut.
Time & Date Changed
625
000
Time & Date has been changed
Keypad Bus Trouble
330
001 to 008
Keypad device 1-8 offline
RF Receiver jam detected
344
000
RF Jamming Detected
Dialler Failure
354
000
Failure to get kiss off
Listen-In Request
606
000
Hold line open after alarm