7
2k2
Ta mper
4k7
8k2
Ta mper
Alarm or Key-sw itch 1 Contact
Alarm or Key-sw itch 2 Contact
NC or NO
NC or NO
INPUTS
The ‘
S
series’ has 9 separate programmable monitored analogue inputs,
8 x
Programmable, multi-state detection inputs which include Zone Doubling options
1 x
Programmable tamper input ( with optional Key-switch functions)
Each input must be terminated with the appropriate value or combination of end-of-line resistors, even if the input is
unused.
ZONE INPUTS
- Each of the 8 zone inputs can be assigned one of the following End of Line (EOL) configuration options,
Zone EOL Type (P125E)
Input Resistor
Comments
0
(Short circuit)
Loop EOL
1
1k (Brown, Black, Red)
Single EOL
2
1k5 (Brown, Green, Red)
Single EOL
3
2k2 (Red, Red, Red)
Single EOL
4
3k3 (Orange, Orange, Red)
Single EOL
5
3k9 (Orange, White, Red)
Single EOL
6
4k7 (Yellow, Violet, Red)
Single EOL
7
5k6 (Green, Blue, Red)
Single EOL
8
6k8 (Blue, Grey, Red)
Single EOL
9
10k (Brown, Black, Orange)
Single EOL
10
12k (Brown, Red, Orange)
Single EOL
11
22k (Red, Red, Orange)
Single EOL
12
2k2 Tamper, 4k7 Zone
Zone & Tamper
13
3k3 Tamper, 6k8 Zone
Zone & Tamper
14
2k2 Tamper, 4k7 Low Zone, 8k2 High Zone
Zone Doubling, with Tamper
15
4k7 Low Zone, 8k2 High Zone
Zone Doubling, No tamper
Type 1-11 (Single EOL no Tamper)
Type 14 (Zone Doubling with Tamper)
n/c
n/o
EOL Resistor
Type 0 (Short/Loop Circuit)
n/c
Type 12-13 (Single Zone with Tamper)
2k2 or 3k3
A larm Contact
n/c or n/o
4k7 or 6k8
Ta mper Resistor