88
4+2 PROGRAM OPTIONS
When using the 4+2 Reporting Format the two digit report code can be changed if desired at the locations below. Also
the two digit codes can include the numbers 0-9 as well the special characters B,C,D,E & F. The chart below shows how to
program the special 4+2 characters.
ARMED by USER 4+2 CODE
ARMED by USER 4+2 CODE
- P16E 1-100E User Number (Value 00-FF)
DISARMED by USER 4+2 CODE
DISARMED by USER 4+2 CODE
- P17E 1-100E User Number (Value 00-FF)
ZONE ALARM 4+2 CODE
ZONE ALARM 4+2 CODE
- P147E 1-16E Zone Number (Value 00-FF)
ZONE ALARM RESTORE 4+2 CODE
ZONE ALARM RESTORE 4+2 CODE
- P148E 1-16E Zone Number (Value 00-FF)
ZONE NEAR ALARM 4+2 CODE
ZONE NEAR ALARM 4+2 CODE
- P149E 1-16E Zone Number (Value 00-FF)
ZONE NEAR ALARM RESTORE 4+2 CODE
ZONE NEAR ALARM RESTORE 4+2 CODE
- P150E 1-16E Zone Number (Value 00-FF)
ZONE VERIFIED ALARM 4+2 CODE
ZONE VERIFIED ALARM 4+2 CODE
- P151E 1-16E Zone Number (Value 00-FF)
ZONE VERIFIED ALARM RESTORE 4+2 CODE
ZONE VERIFIED ALARM RESTORE 4+2 CODE
- P152E 1-16E Zone Number (Value 00-FF)
ZONE BYPASS 4+2 CODE
ZONE BYPASS 4+2 CODE
- P155E 1-16E Zone Number (Value 00-FF)
ZONE BYPASS RESTORE 4+2 CODE
ZONE BYPASS RESTORE 4+2 CODE
- P156E 1-16E Zone Number (Value 00-FF)
MAINS FAIL 4+2 CODE
MAINS FAIL 4+2 CODE
- P195E 1E (Value 00-FF)
MAINS FAIL RESTORE 4+2 CODE
MAINS FAIL RESTORE 4+2 CODE
- P195E 2E (Value 00-FF)
BATTERY LOW 4+2 CODE
BATTERY LOW 4+2 CODE
- P195E 3E (Value 00-FF)
BATTERY LOW RESTORE 4+2 CODE
BATTERY LOW RESTORE 4+2 CODE
- P195E 4E (Value 00-FF)
SYSTEM TAMPER 4+2 CODE
SYSTEM TAMPER 4+2 CODE
- P195E 5E (Value 00-FF)
SYSTEM TAMPER RESTORE 4+2 CODE
SYSTEM TAMPER RESTORE 4+2 CODE
- P195E 6E (Value 00-FF)
DTMF or PC ARM 4+2 CODE