48
MISCELLANEOUS USER OPTIONS
- P25E 13E
Option 1 - Code Required to View Memory
Option 2 - Cancel Handover Zone Function in Stay Mode
Option 3 - Output Control from Keypad is Disabled when Armed
Option 4 - Keypad Codes are Disabled During Entry Delay
Option 5 - No Keypad Indications while Armed
Option 6 - Monitored KP Buss Output Board
Option 7 - Enable Keypad Tamper Switch Alarms
Option 8 - Limit Events & Dialler to 3 of any one type
Option 1
Code Required to View Memory
- If this option is turned on, access to Memory Mode will only be
allowed by using an authorised code. The user must press <MEMORY> <CODE #> <ENTER> to view
memory events Codes are authorised by turning on option 8 at location P4E. If this option is turned off
anyone can access memory mode.
Option 2
Cancel Handover Zone Function in Stay Mode
- If this option is turned on, any zone programmed with
the handover feature will act as a normal delayed zone during Stay mode (ie the handover feature will be
ignored). The zone will still have the normal handover feature during the full arm state.
Option 3
Output Control from Keypad is Disabled when Armed
- If this option is turned on any User code
programmed to operate an output for access control will be disabled when the area/s assigned to the
user code is/are armed (P3E). If the user code is assigned to area A but area B was armed the code can
still operate the output. If no areas are assigned at P3E this option has no effect on the User code.
Option 4
Keypad Codes are Disabled During Entry Delay
- If this option is turned on no codes will operate during
the entry delay. This forces the user to disarm before entering the premises.
Option 5
No Keypad Indications while Armed
- If this option is turned on and all areas assigned to keypads are
armed, the keypad display will be blank during the armed state. If any keypad is assigned to areas A&B at
location P71E, both areas must be armed before the display will go blank on arming.
Option 6
Monitored KP Buss Output Board
- This option performs a similar function to option 6 at location
P25E10E in that if it is turned on the Output status messages are sent to the keypad buss. The difference
with this option is when turned on the panel is expecting the OUTPUTX4 board connected to the keypad
buss to acknowledge the messages. If the OUTPUTX4 does not acknowledge the output status messages
the panel will show an output board failure. This option should only be turned on if an OUTPUTX4 board
with the latest software is connected to the keypad buss.
Option 7
Enable Keypad Tamper Switch Alarms
- If this option is turned off the panel will ignore all alarms
generated by keypad tamper switches. To enable the keypad tamper alarms this option must be turned
on.
Option 8
Limit Events & Dialler to 3 of any one Type
- If this option is turned on the panel will not record any
more than 3 events in memory for any event type during a single arm or disarm cycle, eg if the AC failed 4
times while armed or disarmed the panel will only record the AC fail 3 times in memory and will only
report the AC fail 3 times to the dialler. As soon as the arm state has changed any counts are reset back
to zero again. If this option is off there is no limit on the recording and reporting of events.
SETTING REAL TIME CLOCK
REAL TIME CLOCK HOUR/MINUTE
P26E 1E
(Value 0-2359)
REAL TIME CLOCK DAY of WEEK
P26E 2E (Value 1-7) [where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc]
REAL TIME CLOCK DATE/MONTH/YEAR
P26E 3E (Value DDMMYY) (for example 020904 = 2nd September, 2004)
The Real Time Clock controls the Time-zones, the timing of automatic test calls and is used to Time & Date stamp the
events in the Event Buffer. Ensure this is set correctly at the time of installation so that the all of the functions using the
time will work correctly. The clock is programmed in 24 hour format (eg 00:00-23:59).
DAYLIGHT SAVING (DLS) SETTINGS
DAYLIGHT SAVING ACTIVE -
P26E 4E (If LED # 1 is On, Daylight Saving is currently active)
NOTE
: If you are in Daylight Saving Time when the alarm system is installed you MUST turn on option 1 at location