manualshive.com logo in svg
background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ELECTRICAL INSTALLATION 

 

Electrical Interface 

 

The Optiport E-2 is uses a standard RJ45 8-Way connector as its 
electrical interface, which provides a simple solution for the user to 
setup their system using a standard RJ45 8-Way data cable. The 
signal layout of the connector is as follows : 
 
 
 
 
 
 
 
 
 
 
 
 

Cable Requirements 

 

Standard 8-way data cables with plugs are available from Invertek 
Drives Ltd on request. 
If the data cable is made up on site, ensure that the connection pin 
out is correct : Pin 1 to Pin 1,   Pin 8 to Pin 8 etc. 
 
 
 
 
 
 
 

CAUTION

 

Incorrect cable connection may damage the drive. Extra care should 
be taken when using third party cable. 

 

System Setup 

 

The Optidrive E-2

 

provides the +24V power supply to the Optiport E-2 

via RJ45 connection. Once the physical connection has been setup, 
the system is ready to operate. See picture blow:

 

 
 

 

MECHANICAL INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

DIMENSIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

THROUGH PANEL MOUNT 

 
The panel on to which the Optiport E-2 is to be mounted should be cut 
out in accordance with the diagram below. 

 

 

SAFETY 

 

Optiport E-2 is designed to be used in conjunction with the Optidrive E-
2 variable speed drive and is intended for professional incorporation 
into complete equipment or systems. The Optiport E-2 can be used to 
control the operation of the Optidrive E-2 range.  The drive must be 
installed correctly to prevent a safety hazard. The Optidrive E-2 uses 
high voltages and currents, carries a high level of stored electrical 
energy, and is used to control mechanical plant that may cause injury. 
Close attention is required to system design and electrical installation to 
avoid hazards in either normal operation or in the event of equipment 
malfunction.  
 
System design, installation, commissioning and maintenance must be 
carried out only by personnel who have the necessary training and 
experience. They must read carefully this safety information and the 
instructions in this and the Optidrive E-2 User Guide and follow all 
information regarding transport, storage, installation and use, including 
the specified environmental limitations. 
 

Please read the IMPORTANT SAFETY INFORMATION below, and 
all Warning and Caution boxes elsewhere. 

 
 

SAFETY NOTICES 

 

WARNING

 

is given where there is a hazard that could lead to injury or 

death of personnel. 

CAUTION

 is given where there is a hazard that could lead to damage 

to equipment. 

 
 
 
 
 
 

       

 

 

Dr David Jones, R&D Director

 

 

DECLARATION 

 
All rights reserved. No part of this User Guide may be reproduced or 
transmitted in any form or by any means, electrical or mechanical 
including photocopying, recording or by any information storage or 
retrieval system without permission in writing from the publisher. 
 

Copyright Invertek Drives Ltd ©

 2007 

 

The manufacturer accepts no liability for any consequences resulting 
from inappropriate, negligent or incorrect installation, or adjustment of 
the optional operating parameters of the drive or from mismatching of 
the drive to the motor. 
 
The contents of this User Guide are believed to be correct at the time 
of printing. In the interests of a commitment to a policy of continuous 
improvement, the manufacturer reserves the right to change the 
specification of the product or its performance or the contents of the 
User Guide without notice. 

 

 

WARRANTY 

 
All Invertek Drives Ltd (IDL) products carry a 2-year warranty, valid 
from the date of manufacture. This date is clearly visible on the rating 
label. 

 

Complete Warranty Terms and Conditions are available upon request 

to your IDL Authorised Distributor. 

 
 

 

 

OPTIPORT E-2 

 

Remote Keypad Option Module 

 

User Guide 

 

Installation and Operating Instructions 

 
 

 

 

IMPORTANT SAFETY INFORMATION 

 

Safety of machinery, and safety-critical applications 

 
The level of integrity offered by the Optiport E-2 / Optidrive E-2

 

control 

functions – for example stop/start, forward/reverse and maximum 
speed, is not sufficient for use in safety-critical applications without 
independent means of protection. All applications where malfunction 
could cause injury or loss of life must be subject to a risk assessment 
and further protection provided where needed.  
 
Within the European Union, all machinery in which this product is used 
must comply with Directive 89/392/EEC, Safety of Machinery. In 
particular, the electrical equipment should comply with EN60204-1. 
 

 

CONFORMITY WITH STANDARDS FOR OPTIDRIVE 

 

 

CE-marked for Low Voltage Directive. 

 

EN61000-4 EMC Generic Emissions Standard, Industrial Level. 

 

EN61000-2 EMC Generic Immunity Standard, Industrial Level. 

 

Enclosure ingress protection, EN60529, NEMA 250. 

 

Flammability rating according to UL 94. 

 

GENERAL SPECIFICATION 

 
Signal Interface: 

Standard 6-way RJ45 connector  

Supply Input: 

10V … 36V DC, 30mA 

RS485 signal: 

industry standard 2-wire +5V differential 

Environmental: 

Operational 

0 … 50 

°

Storage  

-40 

°

C … 60 

°

Relative Humidity  < 95% (non condensing) 

Protection rating: 

IP54 

Max cable length:  20m (unscreened, total length) 
 

 

100m (screened, twisted pair, total length) 

WARNING

  

 

When installing the Optiport E-2, all Optidrives should be 
disconnected and 

ISOLATED

 before attempting any work. High 

voltages are present at the terminals and within the drive for up to 10 
minutes after disconnection of the electrical supply. The Optidrives 
should be installed by qualified electrical persons and in accordance 
with local and national regulations and codes of practice.  

 Refer to the Optidrive E-2

 

manual for further details. 

CAUTION  

 Carefully inspect the Optiport before installation to ensure it is 

undamaged. 

 Store the Optiport in its box until required. Storage should be clean 

and dry. Temperature range -40

o

C to +60

o

C. 

 Install the Optiport on a flat, flame-resistant vibration-free surface. 

 Flammable material should not be placed close to the Optiport. 

 

81 

66 

55 

23 

Unit: mm 

65 

70 

55 

Panel 

Cut Out 

Unit: mm 

8-way ribbon cable with leader 

 

RJ45 Interface 

Electromagnetic Compatibility (EMC) 

 
 

Optidrive is designed to high standards of EMC. EMC data is provided 
in a separate EMC Data Sheet, available on request. Under extreme 
conditions, the product might cause or suffer disturbance due to 
electromagnetic interaction with other equipment. It is the 
responsibility of the installer to ensure that the equipment or system 
into which the product is incorporated complies with the EMC 
legislation of the country of use. Within the European Union, 
equipment into which this product is incorporated must comply with 
89/336/EEC, Electromagnetic Compatibility. 
 
When installed as recommended in this User Guide, the radiated 
emissions levels of all Optidrives are less than those defined in the 
Generic radiated emissions standard EN61000-6-4. The conducted 
emission levels are less than those defined in the Generic radiated 
emissions standard EN61000-6-4 (class A) for the specified motor 
cable lengths. 
 

RJ45 Interface Signal Layout 

NC 
NC 
0V 
RS485 - / Optibus 
RS485 + / Optibus 
+24V 
NC 
NC 
 

Отзывы: