background image

Digiplex & DigiplexNE 

 -

 1 

 

Module

Programming Guide

48-Zone LED Keypad Module

This model does not support installer programming capabilities, therefore you cannot program other modules or the panel on the
combus using this unit.

*000=disabled; 001=A1; 002=A2; 003=A3; 004=A4.

Do not assign the same display number to more than one section. A maximum of 4 partitions can be displayed on the keypad. 

U

 = 

Default Settings

Section

Data

Description

Default

[001]

__/__/__ (000 to 004)*

Partition 1 Display

001 = (LED A1)

[002]

__/__/__ (000 to 004)*

Partition 2 Display

002 = (LED A2)

[003]

__/__/__ (000 to 004)*

Partition 3 Display

003 = (LED A3)

[004]

__/__/__ (000 to 004)*

Partition 4 Display

004 = (LED A4)

[005]

__/__/__ (000 to 004)*

Partition 5 Display

000

[006]

__/__/__ (000 to 004)*

Partition 6 Display

000

[007]

__/__/__ (000 to 004)*

Partition 7 Display

000

[008]

__/__/__ (000 to 004)*

Partition 8 Display

000

SECTION [009] : Keypad Options

SECTION [010] : Beep on Trouble

Option

OFF

ON            

Option

OFF

ON            

[1]

Confidential Mode

U

 

Disabled

N

 Enabled

[1]

Beep on System Trouble/Clock Loss

U

 

Disabled

N

 Enabled

[2]

Exit Confidential Mode

U

 

Press key

N

 Enter code

[2]

Beep on Communicator Trouble

U

 

Disabled

N

 Enabled

[3]

Muting

U

 

Disabled

N

 Enabled

[3]

Beep on Module/Combus Trouble

U

 

Disabled

N

 Enabled

[4]

Beep on Exit Delay

 

N

 Disabled

U

 

Enabled

[4]

Beep on Zone Trouble

U

 

Disabled

N

 Enabled

[5]

Chime on Zone Closure

U

 

Disabled

N

 Enabled

[5] to [8]

Future Use

 

N

 N/A

 

N

 N/A

[6] to [8]

Future Use

 

N

 N/A

N

 N/A

SECTION [011] : PGM & Keypad Tamper Options

Option

OFF

ON            

[1]

PGM State

U

 

N.O.

 

N

 N.C.

[2]

PGM Deactivation Mode

U

 

Deactiva-

tion Event

N

 PGM Timer

[3]

PGM Base Time

U

 

1 second

 

N

 1 minute

[4]

Future Use

 

N

 N/A

N

 N/A

[5]

Keypad Tamper

U

 

Disabled

 

N

 Enabled

[6] to [8]

Future Use

 

N

 N/A

 

N

 N/A

DGP2-648

Summary of Contents for Digiplex DGP2-648

Page 1: ...Display 000 007 __ __ __ 000 to 004 Partition 7 Display 000 008 __ __ __ 000 to 004 Partition 8 Display 000 SECTION 009 Keypad Options SECTION 010 Beep on Trouble Option OFF ON Option OFF ON 1 Confid...

Page 2: ...72 000 109 __ __ __ Zone 9 009 141 __ __ __ Zone 41 041 173 __ __ __ Zone 73 000 110 __ __ __ Zone 10 010 142 __ __ __ Zone 42 042 174 __ __ __ Zone 74 000 111 __ __ __ Zone 11 011 143 __ __ __ Zone 4...

Page 3: ...Digiplex DigiplexNE 3 Modules Programming Guide Module Connection Drawings MODULE CONNECTION OVERVIEW...

Page 4: ...Digiplex DigiplexNE 4 Modules Programming Guide LCD KEYPAD MODULE DGP2 641 48 ZONE LED KEYPAD MODULE DGP2 648 ANNUNCIATOR MODULE DGP2 ANC1...

Page 5: ...ent occurs or after a period of time The PGM Deactivation Option determines which method is used the PGM Deactivation Event or the PGM Timer Enter the section that corresponds to the desired PGM and e...

Page 6: ...002 User Codes 512 to 767 000 to 255 000 to 255 003 User Codes 768 to 999 000 to 231 000 to 231 255 Any User Code Not Used Not Used 010 Arming with User Code 000 User Codes 001 to 255 001 to 255 001 t...

Page 7: ...5 002 User Codes 512 to 767 000 to 255 000 to 255 003 User Codes 768 to 999 000 to 231 000 to 231 255 Any User Code Not Used Not Used 021 Alarm Cancelled with Keyswitch 000 Keyswitch numbers 001 to 03...

Page 8: ...Auxiliary Current Limit 003 003 Bell Current Limit 004 004 Bell Absent 005 005 Clock Trouble 006 006 Global Fire Loop 007 007 255 Any trouble event Not Used Not Used 037 Trouble Restore 000 TLM Troubl...

Page 9: ...002 User Codes 512 to 767 000 to 255 000 to 255 003 User Codes 768 to 999 000 to 231 000 to 231 255 Any User Code Not Used Not Used 048 Utility Key 000 Utility Key 001 to 064 001 to 064 001 to 064 25...

Page 10: ...nes Bypassed 005 005 Bypass Master Installer Programming 006 006 Keypad Lockout 007 007 066 Status 3 See Note 1 on page 44 Intellizone Delay Engaged see Note 4 on page 44 000 000 Fire Delay Engaged 00...

Page 11: ...Actions Keypad Utility Keys Keyswitch Inputs definition 3 Keyswitch Inputs definition 4 Remote Control Utility Key Event 13 N A KS Input 13 opens KS Input 7 opens N A Utility Key Event 14 N A KS Input...