Security Products 

 

 

  

SPCK620/623 
Comfort Keypad 

User Guide 
 
 

Version 3.1  

 

Summary of Contents for SPCK620

Page 1: ...A6V10271018 Siemens AB 26 09 2011 Security Products SPCK620 623 Comfort Keypad User Guide Version 3 1 ...

Page 2: ...ocument and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Edition 26 09 2011 Document ID A6V102710...

Page 3: ...1 Login with PIN 13 4 2 Login with card SPCK623 13 4 3 Login with PIN and card SPCK623 13 5 Single area view 14 5 1 Setting and unsetting the system 14 5 2 Setting not possible 14 5 3 Restoring an alarm 15 5 4 Resetting a fault 16 6 Multi area view 18 6 1 Setting and unsetting the system 18 6 2 Setting not possible 19 6 3 Restoring an alarm 20 6 4 Resetting a fault 21 6 5 Automatic Calendar Settin...

Page 4: ...1 6 EVENT LOG 31 7 1 7 CHIME 31 7 1 8 USERS 31 7 1 8 1 ADD 31 7 1 9 CHANGE PIN 32 7 1 10 SMS 33 7 1 10 1 SMS CONTROL 33 7 1 10 2 SMS EVENTS 34 7 1 10 3 SMS Commands 35 7 1 11 DOOR CONTROL 36 7 1 12 GRANT ACCESS 37 7 1 13 REPORT TO ENG 37 7 1 14 ACCESS LOG 37 8 Appendix 39 8 1 User rights 39 8 2 Zone chart 41 ...

Page 5: ...dditional country specific local safety standards or regulations concerning project planning operation and disposal of the product Liability claim Do not make any changes or modifications to the device unless they are expressly mentioned in this manual and have been approved by the manufacturer 1 2 2 Operation Dangerous situation due to false alarm Make sure to notify all relevant parties and auth...

Page 6: ... notices Signal Word Type of Risk DANGER Danger of death or severe bodily harm WARNING Possible danger of death or severe bodily harm CAUTION Danger of minor bodily injury or property damage IMPORTANT Danger of malfunctions 1 4 Meaning of hazard symbols WARNING Warning of hazard area WARNING Warning of dangerous electrical voltage ...

Page 7: ...encies at Siemens AB Building Technologies Division International Headquarters Fire Safety Security Products Postal Address P O Box 1275 SE 171 24 Solna Sweden European Directive 2004 108 EC Electromagnetic Compatibility Compliance with the European Directive 2004 108 EC has been proven by testing according to the following standards emc emission EN 55022 Class B emc immunity EN 50130 4 European D...

Page 8: ...LCD for easy operation The functionality can be enhanced with key switch expander SPCE110 or indication expander SPCE120 The SPCK623 is equipped with a proximity card reader 125 kHz EM 4102 for easy user access soft keys large graphical LCD and voice annunciation support The functionality can be enhanced with key switch expander SPCE110 or indication expander SPCE120 1 LED status indicators The LE...

Page 9: ...habetic characters are selected by applying the appropriate number of key presses To switch between upper and lower case characters press the hash key To enter a numeric digit hold down the appropriate key for 2 seconds 8 Multi functional navigation key Navigation through menus and to scroll through alert messages See Display Message Prioritization below 9 Information key Displays information Prio...

Page 10: ...XBUS Power supply link Engineer restore Required System information Soaked zones Open zones Area state Low battery sensor Sensor lost WPA Low battery WPA lost WPA Test overdue Camera offline Reboot Hardware fault Aux over current Battery low 3 1 LED description Description Symbol Color Operation Description Information Blue On The system or area cannot be set Forced setting is possible faults or o...

Page 11: ...n be seen in idle state 3 2 Viewing mode description There are 2 viewing modes automatic Multi area view User has access to several areas Displaying the areas is done via area groups If no area group is configured only the general group All my areas is displayed Single area view The user has only rights for 1 area In the single area view only one area is displayed in large fonts and can be control...

Page 12: ...ncy keys are displayed A simultaneous pressing of the keys activates an emergency call Panic Alarm Fire alarm Medical Alarm The activated process depends on the system configuration Please ask the installer for details Direct Settings Depending on configuration the direct set option is displayed A forced set part set without PIN is possible of the area the keypad is assigned to ...

Page 13: ...ked for one minute Wait for this amount of time and subsequently enter the PIN correctly 4 2 Login with card SPCK623 The card pace must be assigned to a user and stored in the control panel Present the card to the card reader of the keypad The card reader receiving area is next to the alphanumeric keypad and is indicated by following icon 4 3 Login with PIN and card SPCK623 The card and PIN option...

Page 14: ...lid User code The following screen will be displayed 2 Press the relevant context sensitive function key to change the state of the area Following states are possible Symbol Function Fullset Unset Partset A Partset B 5 2 Setting not possible If there is e g an open zone the setting symbol will be displayed with an information symbol Press the softkey below the setting symbol ...

Page 15: ... zone attribute Exit open is enabled The Entry Exit zone is open Zone will not prevent setting process Zone has to be closed at the end of the exit timer If the zone is still open setting will fail 5 3 Restoring an alarm If there is any alarm the alarm will be displayed after login 1 The alarm will be displayed by the blinking symbol and the blinking LED 2 Press the softkey below the blinking alar...

Page 16: ...icated after closing according zone e g window Alarm can be restored If the alarm can be restored press the softkey below the symbol The alarm is restored 5 4 Resetting a fault If there is any fault this will be displayed after login The symbol is blinking The LED is blinking 1 Press the softkey below the blinking fault symbol NOTICE The location of the different setting softkeys is fixed Due to t...

Page 17: ...ough the lists of faults 4 Highlight the required fault There are 2 fault symbols to indicate possible actions Fault can not be restored Fault condition still present Please contact your installer Fault can be restored If the fault can be restored press the softkey below the symbol The fault is restored Ready will be shown on the display ...

Page 18: ...set Mixed set the areas of the area group have different setting states Partset A all aras of the area group are Partset A Partset B all aras of the area group are Partset B To change the state of an area group 1 Scroll using the keys until the required area group is visible 2 Press the relevant context sensitive function key to change the state of the whole area group To change the state of a sin...

Page 19: ... groups are visible 1 Scroll using the keys until the required area is visible 2 Press the softkey below the setting symbol In the next screen the information about that zone will be shown Following states are possible Symbol Function None This open zone can be inhibited forced set is possible This open zone can not be inhibited no forced set possible Please contact your installer if symbol is sti...

Page 20: ...inking LED NOTICE There is a fixed soft key assignment to set partset unset areas or area groups Due to this the location of the alarm icon can vary In the graphics below there is an alarm in fullset condition 1 Scroll using the keys until the required area group is visible 2 Press 3 Scroll using the keys until the required area is visible 4 Press the softkey below the blinking alarm symbol In the...

Page 21: ...arm can be restored If the alarm can be restored press the key The alarm is restored 6 4 Resetting a fault If there is any fault this will be displayed after login The symbol is blinking The LED is blinking NOTICE In the below pictures a system wide fault e g X Bus cable fault is indicated Due to this the fault symbol is displayed behind all area groups areas It is sufficient to restore the fault ...

Page 22: ... In the above picture there is a fault in unset condition 5 In the next screen the fault s will be listed There are 2 fault symbols possible Fault can not be restored Fault condition still present Please contact your installer Fault can be restored If the fault can be restored press the softkey below the symbol The fault is restored Ready will be shown on the display 6 5 Automatic Calendar Setting...

Page 23: ...nfo symbol Example TIME TO FULLSET 9 MIN 3 SEC To delay setting by the configured time default 30 minutes Press the soft key below the Delay Timer symbol Example TIME TO FULLSET 68 MIN 30 SEC You can press this soft key up to 3 times by default configurable by installer to increment the configured time In this case the icon is no longer displayed To cancel automatic setting for a standard area Pre...

Page 24: ...he same Interlock group only one of the group may be unset at a time A padlock symbol displays next to an interlocked vault or ATM area to indicate that it cannot be unset Once you set one area in the group the padlock symbol is removed to indicate that you can unset another area in the interlock group When a calendar is assigned to an interlocked group to unset automatically the first area listed...

Page 25: ...ucts 26 09 2011 Symbol Function The Interlock symbol indicates if a group of ATM or Vault areas is interlocked Within the interlock group only one area can be unset at a time The padlock symbol displays next to the other areas in the group to indicate that they cannot be unset ...

Page 26: ...amming 1 Enter a valid User PIN 2 Using the up down arrow keys scroll to the desired programming option 3 Within a menu option press to select or enable disable a parameter for example a user right The selected parameter is displayed with an for example Inhibit The keypad displays UPDATED momentarily to indicate a parameter change 7 1 User Menus 1 Enter a valid User PIN 2 Press the right navigatio...

Page 27: ...sers to set up the SMS service for sending short text messages to mobile phones via the PSTN Line 13 DOOR CONTROL Allows the user to control doors He can lock unlock and reset the door to normal operation 14 GRANT ACCESS Allows users to grant Engineer or Manufacturer access to the system 15 REPORT TO ENG Allows the user to request that the last 10 events in the log be sent to the engineer by SMS m...

Page 28: ...SOLATIONS To view a list of the isolated zones system alerts and X BUS devices alerts 7 1 3 INHIBIT Zone and alerts from X BUS devices can be manually inhibited from the keypad Inhibiting a zone removes that zone from the system for one alarm set period only To inhibit zones or alerts from X BUS devices 1 Scroll to INHIBIT and press SELECT 2 Scroll to the desired option in the table below and pres...

Page 29: ... the new date If an attempt is made to save an invalid date value the text INVALID VALUE is displayed for 1 second and the user is prompted to enter a valid date 4 To enter a new time press the required numeric keys To move the cursor to the left and right press the left and right arrow keys 5 Press ENTER to save the new time If an attempt is made to save an invalid time value the text INVALID VAL...

Page 30: ...by the system check the wiring of the sensor and or replace with another sensor if necessary NOTICE Only ALARM ENTRY EXIT and FIRE EXIT are valid zone types which are included in a User walk test 7 1 5 3 WPA TEST To perform a WPA test the installer must have enrolled the WPA 1 Scroll to TEST WPA TEST 2 Press SELECT The keypad display flashes ACTIVATE WPA 3 Press and hold all 3 buttons on the WPA T...

Page 31: ...n one second intervals 1 Scroll to EVENT LOG and press SELECT 2 To view an event from a particular date enter the date with the numeric keys The most recent events are displayed on the bottom line of the display All previous events are displayed for one second in turn 7 1 7 CHIME The chime function can be enabled or disabled on all zones where the chime has been programmed as an audible alert feat...

Page 32: ...to CHANGE PIN and press SELECT A randomly generated PIN appears 2 Select this new PIN or overwrite by entering a new PIN and press ENTER NOTICE If the system is set for 5 digit PINs a new 5 digit PIN must be entered The system will not accept a PIN with fewer numbers than it is set to receive 1 Confirm the new PIN and press SAVE 2 Press BACK to return to the previous screen to amend the PIN During...

Page 33: ...uch as Alarm activation Confirmed alarms Fault tamper Setting unsetting Inhibit isolate All other types of events The SMS notification can operate with a PSTN modem if the PSTN operator supports SMS over PSTN where as SMS control will need a GSM modem at the panel A GSM modem will support both SMS notification and control 7 1 10 1 SMS CONTROL There is a maximum of four users for SMS configuration ...

Page 34: ...and settings 7 1 10 2 SMS EVENTS To receive event notifications SMS setup must have the phone number the number must be enabled for SMS the events must be toggled for SMS Event notification There is a maximum of four users for SMS configuration on one panel and user may set a maximum of 5 phone numbers for SMS receipt Adding a phone number To add a phone number for SMS use 1 Scroll to SMS EVENTS a...

Page 35: ...MS Authentication See page The table below provides all available SMS commands Subsequent action and response are also provided SMS Commands are sent as texts to the phone number of the SIM card on the controller For commands using code the format of the text is the code followed by either a space or a full stop Where is the code and command is the command command or command For example the comman...

Page 36: ...NNN are the numeric placeholders of which not all are necessary Example O5 for mapping gate 5 For SMS recognition X 10 device uses the format XYNN where X stands for X 10 Y stands for the alphabetic identity and NN are the available numeric placeholders Example XA1 The SMS operates using a standard protocol that is used in SMS telephones Please note that some PSTN operators do not provide the serv...

Page 37: ...not access the system until the engineer has logged off To allow engineer access 1 Scroll to GRANT ACCESS and press SELECT 2 Select to ALLOW ENGINEER and select ENABLED 3 Select to ALLOW MANUFACT and select ENABLED 4 To disallow engineer manufacturer access follow the same path and toggle to DISABLED and press SELECT For Swiss CAT 1 and CAT 2 regional requirements when Engineer Access is granted a...

Page 38: ...User programming via the keypad User Menus 38 Siemens AB A6V10271018 Security Products 26 09 2011 3 Scroll down through the access events or enter a date and press ENTER to find a particular access event ...

Page 39: ... Zones that have been classified as EXCLUDE A remain unprotected in this mode By default there is no exit time the system sets instantly on selection of this mode An exit timer can be applied to this mode by enabling the Partset A timed variable Partset B Standard Manager The PARTSET B option applies protection to all zones except those that have been classified as EXCLUDE B By default there is no...

Page 40: ...e time and date on the system Ensure the time and date information is accurate these fields are presented in the event log when reporting system events Test Standard Manager This menu option provides the following test features 1 Bell test The bell test activates the external bells strobe internal bells and buzzer in turn for 5 seconds to ensure their correct operation 2 Walk test A walk test allo...

Page 41: ...etting Unsetting Upgrade Manager User can grant manufacturer access to panel to perform firmware upgrade X 10 Standard Manager Access Control User can activate deactivate configured X 10 devices Door Control Standard Manager Access Control User can lock unlock doors Web Access Standard Manager User can access panel through web browser Outputs Standard Manager User can turn outputs mapping gates on...

Page 42: ...8 Appendix Zone chart 42 Siemens AB A6V10271018 Security Products 26 09 2011 Zone Description ...

Page 43: ...s International Headquarters Englundavägen 7 SE 171 24 Solna Tel 46 8 629 0300 www siemens com securityproducts 2011 Copyright Siemens AB Technical specifications and availability subject to change without notice Document ID A6V10271018 Edition 26 09 2011 ...