42
USER to KEYPAD ASSIGNMENT
USER to KEYPAD ASSIGNMENT
- P10E 1-100E
Option 1 - User will work at Keypad # 1
Option 2 - User will work at Keypad # 2
Option 3 - User will work at Keypad # 3
Option 4 - User will work at Keypad # 4
Option 5 - User will work at Keypad # 5
Option 6 - User will work at Keypad # 6
Option 7 - User will work at Keypad # 7
Option 8 - User will work at Keypad # 8
Any user can be assigned to only operate at certain Keypads. This option controls whether a code or access tag User
can Arm/Disarm from certain keypads. This option does not restrict users from operating outputs from a particular
keypad (this is done at locations P82E & P83E).
RADIO PENDANT PANIC BEEPS to KEYPAD
RADIO PENDANT PANIC BEEPS to KEYPAD
- P11E 21-100E (NOTE: only Users 21-100 can be Radio Users)
Option 1 - A Pendant Panic Alarm will Beep at Keypad # 1
Option 2 - A Pendant Panic Alarm will Beep at Keypad # 2
Option 3 - A Pendant Panic Alarm will Beep at Keypad # 3
Option 4 - A Pendant Panic Alarm will Beep at Keypad # 4
Option 5 - A Pendant Panic Alarm will Beep at Keypad # 5
Option 6 - A Pendant Panic Alarm will Beep at Keypad # 6
Option 7 - A Pendant Panic Alarm will Beep at Keypad # 7
Option 8 - A Pendant Panic Alarm will Beep at Keypad # 8
If a Radio Pendant is programmed to create a Panic Alarm (see P8E), when the Panic Alarm is activated it can be silent
or it can sound the keypad buzzer. Each keypad can be silent during a Pendant Panic Alarm (option turned off) or can
give an audible indication of the Alarm (option turned on).
USER to OUTPUT MASK
USER to OUTPUT MASK
- P12E 1-100E
Option 1 - User is Mapped to Output # 1
Option 2 - User is Mapped to Output # 2
Option 3 - User is Mapped to Output # 3
Option 4 - User is Mapped to Output # 4
Option 5 - User is Mapped to Output # 5
Option 6 - User is Mapped to Output # 6
Option 7 - User is Mapped to Output # 7
Option 8 - User is Mapped to Output # 8
Any user can be allowed to only operate certain Outputs. This Function is mainly used for access control purposes. If
an Output is being used to open a door but a User does not have access through that door, by not allowing the User
to operate that Output access through the door can be denied.
USER can turn an OUTPUT ON
USER can turn an OUTPUT ON
- P13E 1-100E
Option 1 - User can turn ON Output # 1
Option 2 - User can turn ON Output # 2
Option 3 - User can turn ON Output # 3
Option 4 - User can turn ON Output # 4
Option 5 - User can turn ON Output # 5
Option 6 - User can turn ON Output # 6
Option 7 - User can turn ON Output # 7
Option 8 - User can turn ON Output # 8