95
(applies if the User Type, P2E, is set to 1)
Delete a Specific Radio Pendant Code
P19E
21-100E Delete a Specific Radio Pendant Code for Users 21-100
Page 43
(applies if the User Type, P2E, is set to 1)
Find Radio Pendant memory Location
P20E
0E
Enter this address then operate the Radio Pendant to find its user #
Page 44
(applies if the User Type, P2E, is set to 1). Only press 0E when using LED Keypad.
Learn Access Tag/Card Codes
P21E
1-100E
Learn Access Tag/Card Codes for Users 1-100
Page 44
(applies if the User Type, P2E, is set to 2, 3 or 4)
Delete a Specific Access Tag/Card Code
P22E
1-100E
Delete a Specific Access Tag/Card Code for Users 1-100
Page 44
(applies if the User Type, P2E, is set to 2, 3 or 4)
Find an Access Tag/Card memory Location
P23E
0E
Enter this address then operate the Access Tag/Card to find its user #
Page 44
(applies if the User Type, P2E, is set to 2, 3 or 4). Only press 0E when using LED Keypad.
MISCELLANEOUS PANEL & CLOCK SETTINGS
Installer Code
P25E
1E
Installer Code -
( Default = 000000)
Page 44
Duress Digit
P25E
2E
Duress Digit -
Value 1-9 (Default = 0 Duress Function Disabled)
Page 45
Dial Report Delay
P25E
3E
Dial Report Delay -
Value 0-255 seconds (Default = 0)
Page 45
Radio Detector Supervised Timer
P25E
4E
Radio Detector Supervised Timer -
0-9999 Minutes (Default = 60 Minutes)
Page 45
Two Trigger Timer
P25E
5E
Two Trigger Timer -
Value 0-255 Seconds (Default = 60 Sec)
Page 45
Mains Fail Reporting Delay
P25E
6E
Mains Fail Reporting Delay -
Value 0-9999 Seconds (Default = 600 Sec)
Page 45
Receiver Fail Delay
P25E
7E
Receiver Fail Delay -
Value 0-9999 Seconds (Default = 0 Sec-Disabled)
Page 45
Upload/Download Site Code Number
P25E
8E
Upload/Download Site Code Number -
Up to
8 Characters (Default = None)
Page 45
Temporary Output Disable
P25E
9E
Temporary Output Disable -
Output 1-8
Page 46
Miscellaneous Panel Options
P25E
10E
Misc. Panel Options
Miscellaneous Options
Page 46
(Default = 1, 2, 6)
1 = Panel Tamper is 2k2 EOL
2 = Direct access to program mode for the installer code.
3 = Disable Mains Fail Test
4 = Listen-in to O/P # 1 Low Volume
5 = Receiver Fail/RF Jammed Lockout
6 = Send output information to keypad bus
7 = Cannot arm if the system battery is low
8 = Installer Lockout
Installer Options
P25E
11E
Installer Options
Page 47
(Default = All Off)
1 = Entry to installer mode resets confirmed alarms
2 = Entry to installer mode resets tamper alarms
3 = Entry to installer mode resets low battery alarms
4 = Entry to installer mode resets supervisory alarms
5 = Cannot Arm if there is a keypad Fault
6 = Cannot Arm if there is a Telephone Line Failure or Comms Fault
7 = 10 Incorrect Code Attempts locks out the keypad for 90 Seconds
8 = User Codes Must be 4-6 digits long
User Options
P25E
12E
User Options (NOTE: This Option can ONLY be accessed from Client Mode)
Page 47
(Default = All Off)
1 = Hide User Codes from Installer