Keypad “Panic” Alarm 4+2 Reporting Code
P195E 17E
Keypad Panic Alarm 4+2 Code -
Two digit value from 00-FF
Page 89
Keypad “Panic” Alarm 4+2 Restore Reporting Code
P195E 18E
Keypad Panic Alarm Restore 4+2 Code -
Two digit value from 00-FF
Page 89
Keypad “Fire” Alarm 4+2 Reporting Code
P195E 19E
Keypad Fire Alarm 4+2 Code -
Two digit value from 00-FF
Page 90
Keypad “Fire” Alarm 4+2 Restore Reporting Code
P195E 20E
Keypad Fire Alarm Restore 4+2 Code -
Two digit value from 00-FF
Page 90
Keypad “Medical” Alarm 4+2 Reporting Code
P195E 21E
Keypad Medical Alarm 4+2 Code -
Two digit value from 00-FF
Page 90
Keypad “Medical” Alarm 4+2 Restore Reporting Code
P195E 22E
Keypad Medical Alarm Restore 4+2 Code -
Two digit value from 00-FF
Page 90
SIA ALARM REPORT CODES
(SIA event codes are entered by programming a value from the chart on Page 115. For example, to send the SIA “Panic
Alarm” code when a keypad panic is generated you must enter a value of “6” at location P197E1E)
Zone Alarm SIA Reporting Codes
P196E 1-16E
Zone Alarm SIA Reporting Code -
(Default value = 1, Alarm Event Code BA)
Page 90
“Panic” Alarm SIA Reporting Code
P197E 1E
“Panic” Alarm SIA Reporting Code
-
(Default value = 6, Panic Alarm Event Code PA)
Page 90
“Fire” Alarm SIA Reporting Code
P197E 2E
“Fire” Alarm SIA Reporting Code
-
(Default value = 4, Fire Alarm Event Code FA)
Page 90
“Medical” Alarm SIA Reporting Code
P197E 3E
“Medical” Alarm SIA Reporting Code
-
(Default value = 5, Medical Alarm Event Code MA)
Page 90
PANEL DIAGNOSTIC DEFAULT OPTIONS
Display Panel Software Version Number
P200E 1E
Display the Panel Software Version Number
Page 90
Display Keypad Address Number
P200E 2E
Display Keypad Address Number
Page 90
Display Areas Assigned to this Keypad
P200E 3E
Display Areas Assigned to this Keypad
Page 90
Display Active Time Zones
P200E 4E
Display Active Time Zones
Page 90
Display Battery Voltage
P200E 5E
Display Battery Voltage
Page 90
Walk Test Mode
P200E 6E
Walk Test Mode
Page 91
Write to EEPROM (DTU) Board
P200E 7E
Write to EEPROM (DTU) Board
Page 91
Read from EEPROM (DTU) Board
P200E 8E
Read from EEPROM (DTU) Board
Page 91
Restore User & Installer Codes plus Telephone Numbers to Defaults
P200E 9E
Restore User/Installer Codes & Telephone #’s to Default Values
Page 92
Restore All Factory Defaults
P200E 10E
Restore All Factory Defaults
Page 92
Clear Alarm Memory Buffer
P200E 11E
Clear Alarm Memory Buffer
Page 92
Initiate a Call to the Call-back
P200E 12E
Initiate a Call to the Call-back
Page 92