KEY-SWITCH ACCESS & OPERATIONAL OPTIONS
KEY-SWITCH ACCESS & OPERATIONAL OPTIONS
- P112E 1-2E (1 = Key-switch # 1, 2 = Key-switch # 2)
Option 1 - Key-Switch can Arm
Option 2 - Key-Switch can Arm Stay Mode
Option 3 - Key-Switch can Disarm
Option 4 - Key-Switch can Disarm Stay Mode
Option 5 - Key-Switch has Security Guard Options
Option 6 - Key-Switch will Arm Latchkey Mode
Option 7 - Key-Switch is NO (Normally Open)
Option 8 - Key-Switch is Momentary
Option 1
Key-Switch can Arm
- This option enables Arming of the assigned Area via the Key-switch.
Option 2
Key-Switch can Arm Stay Mode
- This option enables Stay Mode Arming of the assigned Area via the Key-
switch.
Option 3
Key-Switch can Disarm
- This option enables Disarming of the assigned Area via the Key-switch.
Option 4
Key-Switch can Disarm Stay Mode
- This option enables Stay Mode Disarming of the assigned Area via the
Key-switch.
Option 5
Key-Switch has Security Guard Options -
If the key-switch has option 5 on, they can Arm all Areas assigned,
but they may only Disarm if the panel is currently Armed and in the alarm state.
Option 6
Key-Switch will Arm Latchkey Mode
- If the panel is armed by a key-switch with this option on, then the
panel will be armed in Latchkey mode. This means that when the alarm is disarmed by a key-switch with this
option off, or a code with option 6 at P4E off, then a disarm report will be sent. The option is designed to
alert the alarm owner when children have returned home and disarmed the alarm.
Option 7
Key-Switch is NO (Normally Open)
- The key-switch can be a NO (Normally Open) or a NC (Normally
Closed) key-switch. The normal, or rest state, of the key-switch can be programmed at this location. If the
key-switch contacts usually rest in the open state and close when the key-switch is operated you should
turn on option 7.
Option 8
Key-Switch is Momentary
- The operation of the key-switch can be momentary or latching. If option 8 is on,
the key-switch operation is assumed to be momentary. This means that each time the key-switch is
operated then released the area will toggle its current state (ie if armed it will become disarmed or vice
versa). If this option is turned off it is assumed that the key-switch is a latching type. This means that when
the key-switch is operated and the key removed the contacts remain in the same state. When a latching key-
switch is used, turning on the switch will arm the area and turning it off will disarm the area.
ZONES
ZONE AREA ASSIGNMENT
ZONE AREA ASSIGNMENT
- P121E 1-16E
Option 1 - Area “A”
Option 2 - Area “B”
Option 1
Area “A”
- This option assigns the Zone to Area A. If a Zone is assigned only to Area A it will activate if Area A
is armed. If the zone is in both area A & B then it will activate only when both areas are armed.
Option 2
Area “B”
- This option assigns the Zone to Area B. If a Zone is assigned only to Area B it will activate if Area B
is armed. If the zone is in both area A & B then it will activate only when both areas are armed.
ZONE OPTIONS A
ZONE OPTIONS A
- P122E 1-16E
Option 1 - Zone is Active
Option 2 - Zone is N/O