51
Option 2 - Output Reset/Chime Timers are in Minutes
Option 3 - Output “Silenced” for 10 seconds on key-press
Option 4 - Turn Output OFF during Two Way Voice Mode
Option 5 - Spare
Option 6 - Spare
Option 7 - Spare
Option 8 - Output Monitored (applies to O/P 1&2 only)
Option 1
Siren Driver to Output
- This option is used to assign a Modulated Siren tone to an Output. The option only
applies to Outputs 1 and 2. For the modulated siren tone to work correctly, an 8
Ώ
speaker must be
connected to the output concerned. Outputs 1 and 2 have different sounds so that a user can tell which
output is operating. If this option is turned on for Outputs 1 and/or 2 it will also inhibit the Output during
two way voice mode (see option 4 below).
Option 2
Output Reset/Chime Timers are in Minutes
- The default setting for the Output reset time (P40E) is in
seconds and the Output Chime time (P41E) is in 1/10th seconds. If longer times are required, this option
turns both the reset and chime times into minutes (eg 1-9999 minutes for the reset time and 1-255 minutes
for the chime time).
Option 3
Output “Silenced” for 10 seconds on key-press
- When the alarm is Armed and activated it can be difficult
sometimes to turn the alarm off because you are unable to hear the beeps as you enter you code at the
keypad. If this option is turned on the selected output/s will silence (turn off) for 10 seconds on the first
button press at any keypad. This should allow easy Disarming of the alarm by a valid User. If the alarm is not
turned off within the 10 seconds, the outputs will turn on again. This function will only work once during an
Armed cycle and the panel must be Disarmed before it will work again.
Option 4
Turn Output OFF during Two Way Voice Mode -
If the panel has a full duplex two way voice board fitted
and the settings at P175E2E option 8 and P183E option 5 are set to allow full duplex mode, any outputs with
this option turned on will be disabled while two way voice is operational. This is to ensure that local sirens
do not interfere with the two way voice audio signal.
Option 8
Output Monitored
- This option is used to allow Monitoring of the Output status (eg wire to siren has been
cut). The option only applies to Outputs 1 and 2.
OUTPUT ON DELAY TIME
OUTPUT ON DELAY TIME
- P38E 1-8E (0-9999 Seconds, 0 = no delay)
The “On” delay allows the operation of the Output to be delayed by the time programmed at this location. If set to “0”
there will be no on delay and the Output will operate the instant it is turned on.
OUTPUT PULSE TIME
OUTPUT PULSE TIME
- P39E 1-8E (0-255 1/10th Seconds, eg 20 = 2 secs)
The Pulse time affects the time the output turns on when the pulse timer is used on the Output. The pulse time is in
1/10th second increments so that very quick timing can be achieved. Functions like radio key Arm/Disarm Chirps to an
Output or a flashing output (P34E option 2) all use the pulse timer. If access tags are assigned with the chirp function
(P46E4E) and the LED on an access reader is set to follow an output with the chirps assigned (P98E) then this timer must
be set to a minimum value of 10 for the reader LED to display the chirps.
OUTPUT RESET TIME
OUTPUT RESET TIME
- P40E 1-8E (0-9999 Seconds, 0 = latched output)
The Reset time affects the time the output turns on when an alarm is active. The default range is 0-9999 seconds but if
option 2 at location P37E is on the range is 0-9999 minutes.
CHIME MODE TIME
CHIME MODE TIME
- P41E 1-8E (0-255 1/10th Seconds, eg 20 = 2 secs)
The Chime Mode time affects the time the output turns on when a Chime Zone is activated. The Chime time is in 1/10th
second increments so that very quick timing can be achieved.