NIGHT MONITOR KEYPAD
The Night Monitor Keypad is designed to be a simple night arming station typically used in a bedroom situation.
By pressing either of the <Night Monitor> buttons the alarm Stay Mode can be armed or disarmed. If both buttons are
pressed simultaneously, a Panic Alarm can be generated. A 4 way DIP switch on the rear of the unit sets various options.
The DIP switch functions and the programming requirements are detailed below.
The Night Monitor keypad can be set to keypad addresses 5-8 by using Switches 1 & 2. Refer to chart below.
Switch 3 is unused on the ‘
S
series’. It is used to force the armed LED to follow area A or B on other control
panels.
Switch 4 MUST be OFF (if Switch 4 is ON the unit will work with earlier version 4 & 5 control panels).
Night Monitor Panel Programming
The Night Monitor button is designed to arm or disarm Stay Mode. The Stay Mode Area is assigned to the keypad at loca-
tion P76E. The functions of the button are programmed at location P77E (eg for the button to Arm Stay Mode and be able
to Disarm Stay Mode at all times you must have options 2 & 4 ON).
The “ARMED” LED function is programmed at location P71E. For example if the Night Monitor keypad is only assigned to
area A and you only want the Armed LED to show the status of area A you should turn on Option 1 (Area A) at location
P71E for the address assigned to the Night Monitor keypad.
If both Night Monitor buttons are pressed simultaneously, it is possible to generate a “PANIC” alarm. To enable the panic
alarm function for the keypad number assigned you must have option 3 turned on at location P72E.
POS
NEG
CLK
DAT
1 2 3 4
ON
A B C
Rear View
PANIC
READY
ARMED
Night
Monitor
Night
Monitor
Front View
DIP Switch â
1
2
KP No: 5
OFF
OFF
KP No: 6
ON
OFF
KP No: 7
OFF
ON
KP No: 8
ON
ON