85
have the battery status monitored.
Option 4
Report Line Fail -
If this option is on the panel will report a Telephone Line fail. The panel will send the line
fail and the line restore at the same time.
Option 5
Report System Tamper -
If this option is on the panel will report a Tamper Alarm on the panel tamper input.
Option 6
Report Keypad Tamper -
If this option is on the panel will report a Tamper Alarm from a keypad fitted with
a tamper switch or a wrong code alarm from a keypad.
Option 7
Report Radio Zone Tamper -
If this option is on the panel will report a Radio Zone Tamper Alarm.
DIALLER REPORTING OPTIONS “B”
DIALLER REPORTING OPTIONS “B” -
P187E 1-8E
Option 1 - Report Duress
Option 2 - Report Supervised Radio Alarm
Option 3 - Report Zone Inactivity Alarm
Option 4 - Report Manual Panic Alarm
Option 5 - Report Manual Fire Alarm
Option 6 - Report Manual Medical Alarm
Option 7 - Report Radio Pendant Panic Alarm
Option 8 - Report Zone Bypasses
Option 1
Report Duress -
If this option is on the panel will report a Duress Alarm (see P25E2E).
Option 2
Report Supervised Radio Alarm -
If this option is on the panel will report a Supervised radio Alarm (see
P25E4E).
Option 3
Report Zone Inactivity Alarm -
If this option is on the panel will report a Zone Inactivity (Sensor-watch)
Alarm (see P163E).
Option 4
Report Manual Panic Alarm -
If this option is on the panel will report a Keypad generated Panic Alarm.
Option 5
Report Manual Fire Alarm -
If this option is on the panel will report a Keypad generated Fire Alarm.
Option 6
Report Manual Medical Alarm -
If this option is on the panel will report a Keypad generated Medical Alarm.
Option 7
Report Radio Pendant Panic Alarm -
If this option is on the panel will report a Panic Alarm generated by a
radio key (pendant).
Option 8
Report Zone Bypasses -
If this option is on the panel will report a Manual or Auto Bypass on a zone.
DIALLER REPORTING OPTIONS “C”
DIALLER REPORTING OPTIONS “C” -
P188E 1-8E
Option 1 - Report Arm/Disarm
Option 2 - Report Stay Mode Arm/Disarm
Option 3 - Report Disarm only after an Alarm
Option 4 - Report Stay Mode Disarm only after an Alarm
Option 5 - Report Stay Mode Zone Alarms
Option 6 - Report Access to Program Mode
Option 7 - Report 24 Hour Alarms for Domestic/Voice Formats
Option 8 - Report Zone Restores
Option 1
Report Arm/Disarm -
If this option is on then all Arm/Disarm signals will be reported to a Monitoring
Station if Contact ID or 4 + 2 is set as the reporting format.
Option 2
Report Stay Mode Arm/Disarm -
If this option is on then all Stay Mode Arm/Disarm signals will be reported
to a Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3
Send Disarm only after an Alarm
- If this option is on, the panel will not normally send an Arm/Disarm
signal to the monitoring company, however, if a zone alarm occurs then the panel will send a Disarm
following the disarming of the panel to show it has been turned off by a valid user.