103
9 to 26 Normal zone mode
Response time = approx 200ms –1sec
Programming the Radio Zone Detector Type
P127E 1-16E
Programming the Radio Zone Type from the List
-
Value = 1-35
Page 71
(Default = 3)
0 = Generic
1 = Crow Merlin PIR (supervised signal ignored)
2 = Crow Merlin PIR (supervised signal active)
3 = Freelink with checksum (supervised signal active)
4 = Freelink with checksum (non-supervised)
5 = Crow AE Series Battery low
6 = Crow AE Radio Reed Switch
11 = Ness Devices battery Low
12 = Ness Radio Reed Switch
31 = Visonic K900 Radio PIR
32 = Visonic Powercode (supervised signal ignored)
33 = Visonic Powercode (supervised signal active)
34 = Siemens (supervised signal ignored)
35 = Siemens (supervised signal active)
Armed Zone Alarms to Outputs
P128E 1-16E
Armed Zone Alarms to Output
Page 72
(Default = 1,2)
1 = A Zone Alarm will Turn On Output # 1
2 = A Zone Alarm will Turn On Output # 2
3 = A Zone Alarm will Turn On Output # 3
4 = A Zone Alarm will Turn On Output # 4
5 = A Zone Alarm will Turn On Output # 5
6 = A Zone Alarm will Turn On Output # 6
7 = A Zone Alarm will Turn On Output # 7
8 = A Zone Alarm will Turn On Output # 8
Armed Stay Mode Zone Alarms to Outputs
P129E 1-16E
Armed Stay Mode Zone Alarms to Output
Page 72
(Default = 2)
1 = A Stay Mode Zone Alarm will Turn On Output # 1
2 = A Stay Mode Zone Alarm will Turn On Output # 2
3 = A Stay Mode Zone Alarm will Turn On Output # 3
4 = A Stay Mode Zone Alarm will Turn On Output # 4
5 = A Stay Mode Zone Alarm will Turn On Output # 5
6 = A Stay Mode Zone Alarm will Turn On Output # 6
7 = A Stay Mode Zone Alarm will Turn On Output # 7
8 = A Stay Mode Zone Alarm will Turn On Output # 8
24 Hour Zone Alarms to Outputs
P130E 1-16E
24 Hour Zone Alarms to Output
Page 72
(Default = All Off)
1 = A 24 Hour Zone Alarm will Turn On Output # 1
2 = A 24 Hour Zone Alarm will Turn On Output # 2
3 = A 24 Hour Zone Alarm will Turn On Output # 3
4 = A 24 Hour Zone Alarm will Turn On Output # 4
5 = A 24 Hour Zone Alarm will Turn On Output # 5
6 = A 24 Hour Zone Alarm will Turn On Output # 6
7 = A 24 Hour Zone Alarm will Turn On Output # 7
8 = A 24 Hour Zone Alarm will Turn On Output # 8
Chime Zone Alarms to Outputs
P131E 1-16E
Chime Zone Alarms to Output
Page 72
(Default = All Off)
1 = A Chime Zone Alarm will Turn On Output # 1
2 = A Chime Zone Alarm will Turn On Output # 2
3 = A Chime Zone Alarm will Turn On Output # 3
4 = A Chime Zone Alarm will Turn On Output # 4
5 = A Chime Zone Alarm will Turn On Output # 5
6 = A Chime Zone Alarm will Turn On Output # 6
7 = A Chime Zone Alarm will Turn On Output # 7
8 = A Chime Zone Alarm will Turn On Output # 8
Zone Tamper Alarms to Outputs
P132E 1-16E
Zone Tamper Alarms to Output
Page 73
(Default = 1,2)
1 = A Zone Tamper Alarm will Turn On Output # 1
2 = A Zone Tamper Alarm will Turn On Output # 2
3 = A Zone Tamper Alarm will Turn On Output # 3
4 = A Zone Tamper Alarm will Turn On Output # 4
5 = A Zone Tamper Alarm will Turn On Output # 5
6 = A Zone Tamper Alarm will Turn On Output # 6
7 = A Zone Tamper Alarm will Turn On Output # 7
8 = A Zone Tamper Alarm will Turn On Output # 8
Armed Zone Alarm Beeps to Keypads
P134E 1-16E
Armed Zone Alarm Beeps to Keypads
Page 73
(Default = All On)
1 = An Armed Zone Alarm will Beep Keypad #1
2 = An Armed Zone Alarm will Beep Keypad #2
3 = An Armed Zone Alarm will Beep Keypad #3
4 = An Armed Zone Alarm will Beep Keypad #4