99
KEYPADS
Keypad Area Assignment
P71E
1-8E
Keypads Assigned To Areas
1 = Area “A”
Page 58
(Default = 1,2)
2 = Area “B”
Keypad Button Options
P72E
1-8E
Keypad Button Options
1 = <CHIME> or <CONTROL><PROGRAM> Button Enabled
Page 58
(Default = All 1,2,3,4,5)
2 = <BYPASS> Button Enabled
3 = <PANIC> Button Enabled
4 = Delayed panic on <PANIC> Button
5 = <1> + <3> or <CONTROL> + <CHIME> Panic Alarm Enabled
6 = <4> + <6> or <A> + <B> Fire Alarm Enabled
7 = <7> + <9> or <B> + <CHIME> Medical Alarm Enabled
8 = Stay Armed Beep to Keypad
Alarm Beeps & LED Control to Keypad
P73E
1-8E
Keypad Beep/LED Options
1 = Mains Fail Beeps Keypad Buzzer
Page 59
(Default = KPI = 1,2,3,5
2 = Fuse Failure Beeps Keypad Buzzer
KP2-8 = 5)
3 = Battery Low Beeps Keypad Buzzer
4 = Telephone Line Failure Beeps Keypad Buzzer
5 = System Tamper Alarm Beeps Keypad Buzzer
6 = Receiver Fail Beeps Keypad Buzzer
7 = Turn Off Keypad LED’s when Armed
8 = Turn Off Keypad & Backlight LED’s on Mains Failure
Keypad “ARM” Button Area Assignment
P74E
1-8E
Keypad “ARM” Button Area
1 = “ARM” Button assigned to Area “A”
Page 60
(Default = 1)
2 = “ARM” Button assigned to Area “B”
Keypad “ARM” Button Area Options
P75E
1-8E
Keypad “ARM” Button Opts.
1 = “ARM” Button can Arm
Page 60
(Default = 1,7)
2 = “ARM” Button can Stay Mode Arm
3 = “ARM” Button can Disarm at All Times
4 = “ARM” Button can Disarm Stay Mode at All Times
5 = “ARM” Button can Reset Alarms
6 = “ARM” Button can Arm Latchkey Mode
7 = “ARM” Button can Disarm During Exit Delay
8 = “ARM” Button can Disarm Stay Mode During Exit Delay
Keypad “STAY” Button Area Assignment
P76E
1-8E
Keypad “STAY” Button Area
1 = “STAY” Button assigned to Area “A”
Page 61
(Default = 1)
2 = “STAY” Button assigned to Area “B”
Keypad “STAY” Button Area Options
P77E
1-8E
Keypad “STAY” Button Opts.
1 = “STAY” Button can Arm
Page 61
(Default K/P 1,2,3,4,6,7,8 = 2,8)
2 = “STAY” Button can Stay Mode Arm
(Default K/P 5 = 2,4)
3 = “STAY” Button can Disarm at All Times
4 = “STAY” Button can Disarm Stay Mode at All Times
5 = “STAY” Button can Reset Alarms
6 = “STAY” Button can Arm Latchkey Mode
7 = “STAY” Button can Disarm During Exit Delay
8 = “STAY” Button can Disarm Stay Mode During Exit Delay
Keypad “A” Button (Portrait LCD KP only) Area Assignment
P78E
1-8E
Keypad “A” Button Area
1 = “A” Button assigned to Area “A”
Page 61
(Default = 1)
2 = “A” Button assigned to Area “B”
Keypad “A” Button (Portrait LCD KP only) Area Options
P79E
1-8E
Keypad “A” Button Opts.
1 = “A” Button can Arm
Page 62
(Default = 1,7)
2 = “A” Button can Stay Mode Arm
3 = “A” Button can Disarm at All Times
4 = “A” Button can Disarm Stay Mode at All Times
5 = “A” Button can Reset Alarms
6 = “A” Button can Arm Latchkey Mode
7 = “A” Button can Disarm During Exit Delay
8 = “A” Button can Disarm Stay Mode During Exit Delay
Keypad “B” Button (Portrait LCD KP only) Area Assignment
P80E
1-8E
Keypad “B” Button Area
1 = “B” Button assigned to Area “A”
Page 62
(Default = 2)
2 = “B” Button assigned to Area “B”
Keypad “B” Button (Portrait LCD KP only) Area Options
P81E
1-8E
Keypad “B” Button Opts.
1 = “B” Button can Arm
Page 63
(Default = All Off)
2 = “B” Button can Stay Mode Arm
3 = “B” Button can Disarm at All Times
4 = “B” Button can Disarm Stay Mode at All Times
5 = “B” Button can Reset Alarms
6 = “B” Button can Arm Latchkey Mode
7 = “B” Button can Disarm During Exit Delay