44
FIND a RADIO PENDANT LOCATION
FIND a RADIO PENDANT LOCATION
- P20E 0E (NOTE: only Users 21-100 can be Radio Pendants)
If you have a Radio Pendant loaded into the panel but are unsure which location (User #), pressing P20E (then 0E on
an LED Keypad) while in Program Mode will start “Find” Mode. There is no need to press 0E when using an LCD keypad
because the keypad will give you written prompts after entering P20E. The keypad will start to beep to indicate that
“Find” mode has been started and the LED on the Receiver will flash. Now press the Radio Pendant button that you
wish to find. If the Radio Pendant is in memory the keypad will display the number (1-16 indicates a zone, and 21-100
indicates a user). The keypad will stop beeping and the LED on the Receiver will stop flashing.
LEARN ACCESS TAG/CARD CODES
LEARN ACCESS TAG/CARD CODES
- P21E 1-100E
An Access Tag/Card must be enrolled into the panel before it can be used. The panel can have up to 100 proximity
tags (key-ring style card), or proximity cards loaded into the system. The tags or cards are stored separately to the
User Codes but they follow the options of Users 1-100 programmed at locations P2E, P3E, P4E, P9E, P10E, P12E, P13E &
P14E. For example if user 11 is assigned to area A (P3E Option 1), and can arm/disarm the alarm (P4E Options 1 & 3),
then access Tag/Card number 11 will arm/disarm area A also.
To learn an Access Tag/Card you must first have a compatible proximity reader connected to the panel keypad buss.
With the reader connected and the panel in program mode, entering P21E then the Access tag/card number you wish
to enrol, eg 11E for Tag/Card number 11, the keypad will start to beep to indicate that learn mode has been started.
Now present the Access Tag/card to the reader. Once the Tag/Card number has been received by the panel and saved,
the keypad will stop beeping to indicate learn mode has stopped. When learning a new access Tag/Card the panel
checks all possible locations before saving the new code to ensure that the code has not already been loaded. If the
tag or card already exists, the panel will not terminate learn mode but instead it will continue looking for a new tag or
card to be presented. This allows a new tag or card to be learnt while existing tags or cards may be in use on the
system. After learning the tag or card, before it will work you MUST select the appropriate option at location P2E
(options 2, 3 or 4 must be selected for the tag to work).
DELETE an ACCESS TAG/CARD CODE
DELETE an ACCESS TAG/CARD CODE
- P22E 1-100E
If you wish to delete a single Access Tag or Card, pressing P22E then the User number while in Program Mode will
delete the stored code against that User, eg P22E 11E will remove the tag or Card stored for User 11.
FIND an ACCESS TAG/CARD LOCATION
FIND an ACCESS TAG/CARD LOCATION
- P23E 0E
If you have an Access Tag or Card loaded into the panel but are unsure which location (User #), pressing P22E (then 0E
on an LED Keypad) while in Program Mode will start “Find” Mode. There is no need to press 0E when using an LCD
keypad because the keypad will give you written prompts after entering P22E. The keypad will start to beep to
indicate that “Find” mode has been started. Now present the Access Tag or Card you wish to find to a proximity reader
connected to the panel. If the Tag or Card is in memory the keypad will display the number where the Tag or Card is
stored (a number from 1-100). The keypad will stop beeping once the memory location has been found.
MISCELLANEOUS PANEL & CLOCK SETTINGS
INSTALLER CODE
INSTALLER CODE
- P25E 1E
This code is used to enter full Installer Program mode (Program LED flashing on LED Keypad). The default installer
code is 000000. This code can only be changed while in Installer Program Mode. To enter your new installer code
press P25E1E. The existing code will displayed at the keypad (either each digit flashed out sequentially on an LED
keypad or shown on the bottom line of the LCD keypad). To change the code simply enter the digits of the new code
and it will replace the old one. The Installer Code must be between 4-6 digits in length.