69
entry zone is triggered first. If no other entry delay zones are triggered before the handover zone the entry
delay on that zone does not apply and the alarm will become instant (no entry delay).
Option 2
Zone is a Two Trigger Zone
- If this option is on the zone will have to trigger twice within the two trigger
time (P25E5E) before it will cause an alarm. If the zone does not trigger a second time before the two trigger
time expires, the count is reset and it will take another two triggers to cause an alarm on this zone. If more
than one zone is set-up as a two trigger zone, then a single trigger from two separate zones within the two
trigger time can also cause an alarm. If the zone becomes faulty and stays in alarm once triggered it will also
cause an alarm provided it remains in alarm for longer than the two trigger time.
Option 3
Zone is a 24 Hour Zone
- If this option is on the zone will be constantly monitored regardless of the arm/
disarm state of the panel. If the 24 Hour zone also has an entry delay programmed (P144E), this delay will
apply. If the 24 Hour zone activates but then resets before the entry delay expires no alarm will be
generated. This feature can be useful for monitoring plant type alarms such as freezer alarms. Once the
alarm has been generated it must be cleared by entry of a valid User code.
Option 4
Zone is a 24 Hour Auto-reset Zone
- If this option is on the zone will be constantly monitored regardless of
the arm/disarm state of the panel. If the 24 Hour zone also has an entry delay programmed (P144E), this
delay will apply. If the 24 Hour zone activates but then resets before the entry delay expires no alarm will be
generated. Once an alarm has been generated with a 24 Hour Auto-reset zone, the alarm will be removed
automatically once the input reseals.
Option 5
Zone is a 24 Hour Fire Zone
- If this option is on the zone will be constantly monitored regardless of the
arm/disarm state of the panel. If the 24 Hour Fire zone also has an entry delay programmed (P144E), this
delay will apply. If the 24 Hour Fire zone activates but then resets before the entry delay expires no alarm
will be generated. Once the alarm has been generated it must be cleared by entry of a valid User code. The
24 Hour Fire Zone will also cause an alarm output to pulse the alarm to differentiate a fire alarm from a
burglar alarm (ie a fire alarm will switch the output on and off at the pulse timer rate whereas a burglar
alarm on the same output will sound continuously).
Option 6
Spare
-
Option 7
Zone is a Chime Zone
- If this option is on, the zone will operate Chime mode when disarmed. When the
alarm is armed the Chime Mode is disabled for this zone. A Chime zone can sound the keypad buzzer or
operate an output to indicate that the zone is unsealed. It is normally used to monitor areas during the
daytime.
Option 8
Zone is a Permanent Chime Zone
- If this option is on, the zone will operate Chime mode when armed or
disarmed. When the alarm is armed the zone will continue to only be a Chime Mode Zone and will not
cause a burglar alarm. A Chime zone can sound the keypad buzzer or operate an output to indicate that the
zone is unsealed.
ZONE OPTIONS C
ZONE OPTIONS C
- P124E 1-16E
Option 1 - Can Arm if Zone is not Ready
Option 2 - Will Send Multiple Reports to Dialler
Option 3 - Zone is Monitored for Inactivity
Option 4 - Zone is on Soak Test
Option 5 - Zone will report to Area B Account Number
Option 6 - Zone will Not Report 24 hour Alarms via Dialler
Option 7 - Pulse Output on Kiss-off Following a Zone Alarm
Option 8 - Exit Terminator Zone
Option 1
Can Arm if Zone is not Ready
- If this option is turned on, plus Options 7 or 8 or on at P45E (cannot Arm if
zones not sealed/Ready), this zone can be unsealed and the panel can still be armed. This option allows the
panel to still be armed if a low security zone is unsealed yet still stopping arming if a high security zone is
unsealed.
Option 2
Will Send Multiple Reports to Dialler
- If this option is turned on, a zone will send an alarm report to the
monitoring station every time it is activated. If the option is turned off, the zone can only send one alarm
report per armed cycle.
Option 3
Zone is Monitored for Inactivity
- If this option is on the zone will be checked to see that it operates during
the disarmed state. If it is not operated within the time set at P163E a “Sensor-watch” alarm will be