53
Option 6
Report Arm Signal at the end of the Exit Delay
- If this option is on the panel will report the Arm signal
to a monitoring station when the exit delay expires. If it is off, the panel will report the arm signal
immediately the system has been armed.
Option 7
Can Arm only if All Zones Sealed (Ready) -
If this option is on it stops the panel from arming an area
with an unsealed zone (Not Ready). If off, the panel can be armed if the Ready LED is not on.
Option 8
Can Arm Stay Mode only if All Zones Sealed (Ready) -
If this option is on it stops the panel from arming
stay mode if an area has an unsealed zone (Not Ready). If off, the panel can be arm stay mode if the
Ready LED is not on.
AREA OPTIONS “B”
AREA OPTIONS “B” -
P46E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Use Near and Verified Alarm reporting for All zones in this Area (CID ONLY)
Option 2 - Area will Arm at the end of Time-Zone
Option 3 - Area will Disarm at the start of Time-Zone
Option 4 - Assign Chirps to Access tags
Option 5 - Spare
Option 6 - Spare
Option 7 - Cannot Arm if Zone Unsealed at end of Exit Delay
Option 8 - Spare
Option 1
Use Near and Verified Alarm reporting for All zones in this Area
- To reduce the possibility of false
alarms the panel can require two alarms on different zones within a 45 minute period before a full alarm
will be sent. If this option is turned on it applies to all zones assigned to that area. An alarm on a single
zone will send a CID (Contact ID) Near Alarm report to the monitoring station. If no further alarms occur
within 45 minutes (and the zone that activated is sealed) the near alarm timer is reset and a restore is
sent for the zone that activated. If the zone that activated is still unsealed when the 45 minute timer
expires, a zone bypass for that zone will be sent and the zone will remain bypassed until the area is
disarmed. Any new alarms after the timer has expired will send another Near Alarm report. If a second
alarm on a different zone occurs within 45 minutes of the Near alarm, an Intrusion Verified alarm report
will be sent. This format only applies to Contact ID and Pager reporting. Turning this option on will stop
zone alarms from being reported in Domestic & Voice formats as there are no messages for near and
confirmed alarms. You must turn this option off if using Domestic or Voice formats.
Option 2
Area will Arm at the end of Time-Zone
- The panel is capable of automatically arming on a Time-Zone. If
this option is turned on and a Time-Zone is selected at P68E, the Area will automatically arm when the
Time-Zone ends. If the panel cannot arm because it is not “Ready”, a fail to arm report will be sent.
Option 3
Area will Disarm at the start of Time-Zone
- The panel is capable of automatically disarming on a Time-
Zone. If this option is turned on and a Time-Zone is selected at P68E, the Area will automatically disarm
when the Time-Zone starts.
Option 4
Assign Chirps to Access Tags
- If the panel is being Armed or Disarmed by an Access Tag/Card from a
proximity reader it is possible to link the pendant chirps programming (P50E-P53E) to Arming or
Disarming via the Access Tag or Card. If this option is On the chirps will apply to Access Tag/Cards. If the
chirps are required to be displayed at the reader LED, the minimum pulse timer for the output (P39E)
must be a value of 10.
Option 7
Cannot Arm if Zone Unsealed at end of Exit Delay
- If this option is turned on and a zone becomes
unsealed as the exit delay expires the panel will fail to arm and report this via the dialler. The unsealed
zone must be corrected and the system re-armed again.
AREA ARM INDICATION to OUTPUT
AREA ARM INDICATION to OUTPUT -
P47E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 5 - Output 5
Option 2 - Output 2
Option 6 - Output 6
Option 3 - Output 3
Option 7 - Output 7
Option 4 - Output 4
Option 8 - Output 8
For monitoring purposes an Arm indication can be assigned to an Output. Each Area can have a separate arm
indication assigned to a different output if required.