86
Option 4
Send Stay Mode Disarm only after an Alarm -
If this option is on, the panel will not normally send a Stay
Mode Arm/Disarm signal to the monitoring company, however, if a zone alarm occurs then the panel will
send a Stay Mode Disarm following the disarming of the panel to show it has been turned off by a valid user.
Option 5
Report Stay Mode Zone Alarms -
If this option is on, the panel will report zone alarms in Stay Mode.
Option 6
Report Access to Program Mode
- If this option is on the panel will report a Contact ID code to indicate that
either Client or Installer program Modes have been accessed.
Option 7
Report 24 Hour Alarms for Domestic/Voice Formats -
When the panel is set to send alarms via domestic or
voice mode, No alarms will normally be sent for 24 hour zones. If 24 hour alarms are required to be
reported in Domestic/Voice mode then this option must be turned on.
Option 8
Report Zone Restores
- If this option is on the panel will report all zone restores in Contact ID or 4 + 2
formats. If this option is turned off the panel will only report the alarms.
DIALLER REPORTING OPTIONS “D”
DIALLER REPORTING OPTIONS “D” -
P189E 1-8E
Option 1 - Report Latchkey Disarm
Option 2 - Report Delinquency Alarm
Option 3 - Report Test Calls
Option 4 - Report Fuse Failure
Option 5 - Report Output 1 or 2 Fail
Option 6 - Report RTC (Real Time Clock) Time changed
Option 7 - Report Keypad Buss Trouble
Option 8 - Report RF Interference (Jamming) Detected
Option 1
Report Latchkey Disarm -
If the panel is armed in Latchkey Report Mode by using a Code, Key-switch,
<ARM>, <STAY>, <A> or <B> buttons, any code or key-switch without the Latchkey option (P4E or P112E
Option 6 off) used to Disarm the Alarm will cause a Latchkey Disarm report to be sent via the dialler. For
Domestic or Voice reporting option 1 at P188E must also be turned ON.
Option 2
Report Delinquency Alarm -
If the panel has been configured for Delinquency monitoring (P67E) and an
area has not been armed for the time set at P67E, a Delinquency Alarm will be sent to the Monitoring
Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3
Send Test Calls
- If Contact ID or 4 + 2 formats are used for reporting alarm, the panel can also send
Automatic test calls. If this option is turned on the test calls will be sent but if test calls are not required they
can be disabled by turning this option off.
Option 4
Report Fuse Failure -
The panel has two on-board thermal fuses designed to protect the 12v DC outputs
from short circuits. If this option is on and either of these fuses are open, a report will be sent to the
monitoring station if Contact ID is set as the reporting format.
Option 5
Report Output 1 or 2 Fail -
The panel has two high current Outputs (O/P 1 & 2). These Outputs are normally
used to drive sirens or strobes for local alarm warning. If option 8 at location P37E is on for either O/P 1 or 2
the Output status will be monitored (eg wire to siren has been cut). If this option is on and a fault is
detected on the output, a report will be sent to the monitoring station if Contact ID is set as the reporting
format
Option 6
Report RTC (Real Time Clock) Time Changed -
If the panel clock is changed and this option is turned on,
the event will be reported to the monitoring station.
Option 7
Report Keypad Buss Trouble -
If any connected keypads are removed from the system they will be reported
as missing if this option is turned on.
Option 8
Report RF Interference (Jamming) Detected -
If the radio receiver detects RF Interference (jamming) of the
radio frequency the panel can report this event to the monitoring station if this option is turned on.
CALL DIVERT TRIGGER EVENTS
CALL DIVERT TRIGGER EVENTS -
P192E 1-2E (1 = Area A Trigger Events, 2 = Area B Trigger Events)