61
KEYPAD <STAY> BUTTON AREA ASSIGNMENT
KEYPAD <STAY> BUTTON AREA ASSIGNMENT
- P76E 1-8E
Option 1 - Area “A”
Option 2 - Area “B”
Option 1
Area “A”
- This option assigns the keypad <STAY> button to Area A. If a keypad <STAY> button is assigned
to only Area A it can only Arm or Disarm that area.
Option 1
Area “B”
- This option assigns the keypad <STAY> button to Area B. If a keypad <STAY> button is assigned
to only Area B it can only Arm or Disarm that area.
KEYPAD <STAY> BUTTON AREA OPTIONS
KEYPAD <STAY> BUTTON AREA OPTIONS
- P77E 1-8E
Option 1 - <STAY> button can Arm
Option 2 - <STAY> button can Arm Stay Mode
Option 3 - <STAY> button can Disarm at All Times
Option 4 - <STAY> button can Disarm Stay Mode at All Times
Option 5 - <STAY> button can Reset Alarms
Option 6 - <STAY> button can Arm Latchkey Mode
Option 7 - <STAY> button can Disarm During Exit Delay
Option 8 - <STAY> button can Disarm Stay Mode During Exit Delay
Option 1
<STAY> button can Arm
- This option enables single button Arming using the <STAY> button. For single
button operation to work options 2 & 3 must be off at location P46E.
Option 2
<STAY> button can Arm Stay Mode
- This option enables single button Arming of Stay Mode using the
<STAY> button. For single button operation to work options 2 & 3 must be off at location P46E.
(NOTE: Following arming of Stay Mode, if the <ENTER> button is pressed, all entry & exit delays will be
reset to zero for that armed period).
Option 3
<STAY> button can Disarm at All Times
- This option enables single button Disarming using the <STAY>
button. For single button disarm operation to work options 2 & 3 must be off at location P46E
Option 4
<STAY> button can Disarm Stay Mode at All Times
- This option enables single button Disarming of Stay
Mode using the <STAY> button. For single button disarm operation to work options 2 & 3 must be off at
location P46E
Option 5
<STAY> button can Reset Alarms
- If this option is On, Pressing the <STAY> button (provided Option 4 is
also On) will reset an alarm condition without having to enter a user code.
Option 6
<STAY> button can Arm Latchkey Mode
- This option enables single button Arming of the alarm in
Latchkey report mode using the <STAY> button. For single button disarm operation to work options 2 & 3
must be off at location P45E. When Latchkey Mode is set on Arming, any code without the Latchkey option
(P4E Option 6) used to Disarm the Alarm will cause a Disarm report to be sent via the dialler.
Option 7
<STAY> button can Disarm During Exit Delay
- This option allows single button Disarming using the
<STAY> button provided the Armed Mode exit delay is active. If the exit delay has expired the <STAY>
button cannot be used to disarm the alarm. For single button disarm operation to work options 2 & 3 must
be off at location P46E
Option 8
<STAY> button can Disarm Stay Mode During Exit Delay
- This option allows single button Disarming of
Stay Mode using the <STAY> button provided the Stay Mode exit delay is active. If the Stay Mode exit delay
has expired the <STAY> button cannot be used to disarm Stay Mode. For single button disarm operation to
work options 2 & 3 must be off at location P46E
KEYPAD <A> BUTTON AREA ASSIGNMENT
KEYPAD <A> BUTTON AREA ASSIGNMENT
- P78E 1-8E (APPLIES TO PORTRAIT LCD KEYPAD ONLY)
Option 1 - Area “A”
Option 2 - Area “B”