background image

6-051344 X2 

1

212iLM Keypad Installation & Programming

PRINTER’S INSTRUCTIONS:

INSTR/PROG,212ILM-AL/212ILM-BZ - P/N: 6-051344 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLDED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1

Speci

fi

 cations

Case Dimensions:

6-1/2” L x 1-3/4” W x 1-1/8” D

Electrical:

Voltage: 12-24 VAC/DC

Current:

53mA@12VDC
72 mA @ 24 VDC
95 mA@12 VAC
108 mA @ 24 VAC

Relay Contacts:

Main Relay (controller): 2 Amps

Bell Relay:

Form A; 1 Amp @ 30 VAC/DC

Environmental:

-20º F to 130° F
For Indoor and Outdoor Use

Features

 

120 User Capacity

 

Programmable Relay Time (0 to 99 seconds)

 

Request to Exit (REX) Input

 

Vandal Resistant Case

 

Sealed for Indoor or Outdoor Applications

 

LED’s for Relay Status Indication

 

Bell Output

 

Surface Mount

 

Illuminated Hardened Keys

 

Rated for Greater than One Million Key Cycles

Applications

 

Low to Medium/Heavy Traf

fi

 c Areas

 

Rough Service Environments

 

Mullion Frame Mounting

 

Dimly Lit Areas

Description:

The Door

Gard Series 212iLM keypad combines 

elegant looks with a mullion mount design in a rugged, 
vandal resistant case, which you can use for almost 
any application. The 212iLM has hardened backlit keys 
designed to perform in medium to high traf

fi

 c areas and 

in rough duty environments. The electronics are also 
conformal coated, which makes the keypad suitable for 
indoor or outdoor applications.

Basic Operation:

To gain access through the door enter your code 
(1-6 digits) followed by the 

 key on the keypad.

Packing List:

(1) 212iLM Keypad
(1) Eight-Conductor Wire Harness
(1) Mullion Hardware Pack
(1) 5/64” Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) Installation/Programming Manual

Wire Harness Con

fi

 guration:

Pin

Wire Color

Signal Name

1

Red

Power (+)

2

Black

Power (-)

3

White/Black

REX

4

White/Yellow

Main Relay NC

5

Blue

Main Relay Common

6

Brown

Main Relay NO

7

White

Bell Relay Contact (A)

8

White

Bell Relay Contact (B)

212iLM Keypad

Installation & Programming Instructions

Note:

 This product is designed to be installed and serviced

by security and lock industry professionals.

Содержание Door-Gard 212iLM

Страница 1: ...ounting Dimly Lit Areas Description The Door Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application...

Страница 2: ...ill the hole for the wires This may vary depending on the number of conductors required Refer to mounting height below Step 2 Wire the keypad using the diagrams in the following sections Step 3 Mount...

Страница 3: ...e connection on your maglock to the negative on the power supply Basic Access Control Using an Electric Door Strike 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire r...

Страница 4: ...X input The normally open REX input triggers the main relay for the amount of time you programmed for the master code If the master code is set to toggle the REX only triggers the relay for 5 seconds...

Страница 5: ...utput when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a doorbell The relay outp...

Страница 6: ...location new code new code Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Fee...

Страница 7: ...Mode Adding User Codes The following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Pr...

Страница 8: ...master code The code you are entering is likely not the master code Perform the program mode loopback in the following section to enter program mode and reprogram the master code No LED s are lit on...

Страница 9: ...he following loopback connection to enter program mode Power down the unit short the wires in the configuration illustrated then power the unit back up The yellow LED should be flashing Now change you...

Страница 10: ...any There are no obligations or liabilities on the part of Nortek Security Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indir...

Страница 11: ...6 051344 X2 11 212iLM Keypad Installation Programming PAGE LEFT BLANK INTENTIONALLY...

Страница 12: ...12 6 051344 X2 212iLM Keypad Installation Programming 212ilM Mounting Template Copyright 2015 Nortek Security Control LLC...

Отзывы: