Nortek Door-Gard 212iLM Скачать руководство пользователя страница 7

6-051344 X2 

7

212iLM Keypad Installation & Programming

Programming Examples

Changing the Master Code

The following example show how to change the master code to 4875 from the default of 1234.

1. Enter Program Mode

99 # 1234 

2. Program New Master Code

1 # 4875 

✱ 

4875 

3. Exit Program Mode

Changing the Main Relay Time

The following example shows how to change the main relay time. The master code is 4875.

1. Enter Program Mode

99 # 4875 

2. Change the Main Relay Time

10 # 1 # 4875 

✱ 

4875 

3. Exit Program Mode

Adding User Codes

The following example shows how to program user 2 with a code of 1749 and user 3 with 9328. The master code is 4875.

1. Enter Program Mode

99 # 4875 

2. Program User # 2

2 # 1749 

✱ 

code 

3. Program User # 3

3 # 9328 

✱ 

code 

4. Exit Program Mode

Programming a Toggle User

The following example shows how to program user 4 as a toggle user with a code of 98773. The master code is 4875.

1. Enter Program Mode

99 # 4875 

2. Change the Main Relay Time

00 # 4 # 98773 

✱ 

98773 

3. Exit Program Mode

LED Indications

LED State

Description

Red Solid

Door Locked

Green Solid

Door Unlocked

Yellow Solid

Programming Error

Yellow Flashing Slowly

Program Mode

Yellow Momentary Flash

Visual Keypress Feedback

Содержание Door-Gard 212iLM

Страница 1: ...ounting Dimly Lit Areas Description The Door Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application...

Страница 2: ...ill the hole for the wires This may vary depending on the number of conductors required Refer to mounting height below Step 2 Wire the keypad using the diagrams in the following sections Step 3 Mount...

Страница 3: ...e connection on your maglock to the negative on the power supply Basic Access Control Using an Electric Door Strike 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire r...

Страница 4: ...X input The normally open REX input triggers the main relay for the amount of time you programmed for the master code If the master code is set to toggle the REX only triggers the relay for 5 seconds...

Страница 5: ...utput when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a doorbell The relay outp...

Страница 6: ...location new code new code Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Fee...

Страница 7: ...Mode Adding User Codes The following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Pr...

Страница 8: ...master code The code you are entering is likely not the master code Perform the program mode loopback in the following section to enter program mode and reprogram the master code No LED s are lit on...

Страница 9: ...he following loopback connection to enter program mode Power down the unit short the wires in the configuration illustrated then power the unit back up The yellow LED should be flashing Now change you...

Страница 10: ...any There are no obligations or liabilities on the part of Nortek Security Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indir...

Страница 11: ...6 051344 X2 11 212iLM Keypad Installation Programming PAGE LEFT BLANK INTENTIONALLY...

Страница 12: ...12 6 051344 X2 212iLM Keypad Installation Programming 212ilM Mounting Template Copyright 2015 Nortek Security Control LLC...

Отзывы: