Nortek Door-Gard 212iLM Скачать руководство пользователя страница 6

6-051344 X2

212iLM Keypad Installation & Programming

Programming the 212iLM Keypad

To program the 212iLM you 

fi

 rst must enter program mode.

To enter program mode enter the following on the keypad: 

99 # master code 

 (default master code is 1234).

Keypad Default Settings

Option

Default Setting

Option

Default Setting

Master Code

1234

Main Relay Time

5 Seconds

Audio Keypress Feedback Enabled

Visual Keypress Feedback Enabled

Auto-Entry

Disabled

Door Bell Select

Continuous

Keypad Illumination

Enabled

Keypad Dimming

Enabled

Programming Options Chart

Command/Action

Keys to Enter/Details

Change Master Code

1 # new code 

✱ 

new code 

Change Main Relay Time

relay time # 1 # master code 

✱ 

master code 

Add/Change User

user location # new code 

✱ 

new code 

Note: Users programmed with this command use master code relay time.

Add Toggle User

00 # user location # new code 

✱ 

new code 

Add User with Speci

fi

 c Relay Time relay time # user location # new code 

✱ 

new code 

Command 30

Set/Clear Keypad Options
(options below, 

defaults in bold

)

30 # option # set/clear # 

✱ ✱

Option

Clear

Set

0 – Audio Keypress Feedback

0 = Disabled

1 = Enabled

1 – Visual Keypress Feedback

0 = Disabled

1 = Enabled

2 – Auto-Entry

0 = Disabled

1 = Enabled

3 – Keypad Illumination

0 = Disabled

1 = Enabled

4 – Keypad Dimming

0 = Disabled (always bright)

1 = Enabled

5 – Door Bell Select

0 = Disabled

1 = Enabled

Command 32

Set Bell Output Time

32 # 0 # time # 

✱ ✱

Set timed output (1 – 99 seconds)

32 # 0 # 0 # 

✱ ✱

Set to continuous

Command 46

Reset Keypad to Default Settings

46 # 00000 # 00000 # 

✱ ✱

Exit Program Mode

Press the 

 Key

Notes:

1.  The 212iLM can store 120 user codes, including the master code. Codes can be from 1 to 6 digits long.
2.  When auto-entry is enabled, users with codes the same length as the master code do not have to press the 

 

key after entering their code to enter the door.

3.  When keypad dimming is disabled the backlighting remains at full intensity (does not dim).
4.  When the door bell output is set to continuous the relay is energized as long the door button is pressed. When 

you release the button the relay de-energizes.

Содержание Door-Gard 212iLM

Страница 1: ...ounting Dimly Lit Areas Description The Door Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application...

Страница 2: ...ill the hole for the wires This may vary depending on the number of conductors required Refer to mounting height below Step 2 Wire the keypad using the diagrams in the following sections Step 3 Mount...

Страница 3: ...e connection on your maglock to the negative on the power supply Basic Access Control Using an Electric Door Strike 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire r...

Страница 4: ...X input The normally open REX input triggers the main relay for the amount of time you programmed for the master code If the master code is set to toggle the REX only triggers the relay for 5 seconds...

Страница 5: ...utput when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a doorbell The relay outp...

Страница 6: ...location new code new code Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Fee...

Страница 7: ...Mode Adding User Codes The following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Pr...

Страница 8: ...master code The code you are entering is likely not the master code Perform the program mode loopback in the following section to enter program mode and reprogram the master code No LED s are lit on...

Страница 9: ...he following loopback connection to enter program mode Power down the unit short the wires in the configuration illustrated then power the unit back up The yellow LED should be flashing Now change you...

Страница 10: ...any There are no obligations or liabilities on the part of Nortek Security Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indir...

Страница 11: ...6 051344 X2 11 212iLM Keypad Installation Programming PAGE LEFT BLANK INTENTIONALLY...

Страница 12: ...12 6 051344 X2 212iLM Keypad Installation Programming 212ilM Mounting Template Copyright 2015 Nortek Security Control LLC...

Отзывы: