background image

800-03612  1/09  Rev. B 

 

ADEMCO 

ADEMCO 

ADEMCO 

ADEMCO 6460S

6460S

6460S

6460S/6460W

/6460W

/6460W

/6460W

REMOTE KEYPAD

REMOTE KEYPAD

REMOTE KEYPAD

REMOTE KEYPAD

INSTALLATION AND SETUP GUIDE 

 

GENERAL INFORMATION 

The ADEMCO 6460S (silver) and 6460W (white) are 
addressable Remote Keypads designed for use with 
Honeywell's ADEMCO series control panels. Addresses are 
set via the keypad keys. 
The keys on the keypad are continuously backlit for 
convenience. 

NOTE:

 If supported, the ADEMCO 6460S and 6460W 

keypads are supervised by control panel. Supervision must 
be enabled for commercial fire installations. 

 

KEYPAD DISPLAYS AND LEDS

 

The ADEMCO 6460S and 6460W keypads have the 
following display features: 

 

2-line Alpha Display 

 

Custom Zone Descriptors 

 

Built-in Speaker Sounder  

 

Dedicated Function Keys 

 

Backlit Display (permanent display backlighting is 
an option on some controls; see the control's 
instructions for details). 

The following table shows the LEDs and their functions: 

LED Function 

Red 

Lights when the system is armed in any mode 

Green 

Lights when the system is "ready" to be armed. 

 

SPECIAL FUNCTION KEYS 

The keypads also feature function keys.  These keys may be 
programmed for panic alarms or other special functions 
such as macros. See the control's instructions for details.  

 

Function keys must be held down for at least 2 

seconds to activate an alarm; key pairs are activated 

immediately.

 

 

Function Keys

 

A or [1] and [

B or [

] and [#] 

C or [3] and [#] 

 

WIRING AND INSTALLATION

 

The keypads can be surface mounted directly to a drywall, 
or to a single- or double-gang electrical box. 

1.  Push the two case release snaps at the bottom of the 

keypad with the blade of a medium screwdriver (this will 
push in the release snap), then pull that side of the case 
back away. Refer to Figure 1 for location of the case back 
release snaps. 

2.  Route wiring from the control panel through the opening 

in the case back. 

3.  Mount the case back to a wall or electrical box.  

4.  Wire directly from the keypad’s terminal block

 

to the 

terminal block on the control panel. (See Wiring Table 
below).  

 
NOTE:

 No more than one wire per terminal may be 

connected. If daisy-chained configuration is required, 
pig-tail wires together so that only one wire is 
terminated under the screw. Use 16-24  AWG wire only! 

 

Wiring Table 

 

Keypad 

Control Panel 

Wire Color 

G

 

Data In

 

Green

 

 

– Aux Pwr (GND)

 

Black

 

+

 

+ Aux. Pwr

 

Red

 

Y

 

Data Out

 

Yellow

 

See the control panel’s Installation and Setup Guide for 
more complete details. 

5.  Reattach the keypad

 

to its case back. 

JKL

AWAY

CODE

ARMED

READY

STAY

OFF

MAX

D

INS

EN

I

GH

RS

PQ

T

TAN

R EADY

BYPASS

C H I ME

TEST

4

6

TUV

9

0

NO

M

X Z

Y

W

UM

N

EF

D

ABC

3

5

8

2

1

7

*

#

NOTE:

TO REMOVE CASE BACK
PUSH IN THE TWO RELEASE
SNAPS LOCATED ALONG THE 
BOTTOM OF THE KEYPAD
AND LIFT UP.

6460S-001-V1

RELEASE

SNAPS

D

C

B

A

 

Figure 1. Removing the Case Back 

WWW.DIYALARMFORUM.COM 

WWW.DIYALARMFORUM.COM

Отзывы: