background image

REPLACEMENT KEYPAD-READ INSTRUCTIONS ON BOTH SIDES

Please note: When the replacement keypad is shipped the jumper pins on the board 
of the keypad are preset for MCS-MAGNUM Revision 7 and higher.

If you have a MCS-MAGNUM lower than revision 7

 (figure 1) you will need 

to change the location of two jumpers located on the replacement keypad 

board as shown in figure 2.

Follow the steps below to use your new replacement keypad.

1.  Locate the MCS-MAGNUM version number 

located on the board.

2.  If you have a MAGNUM revision 7 or higher 

the replacement keypad setup is correct from 
the factory. You can proceed to replace your 
old keypad. 

Follow the instructions on the 

back of this sheet.

3.  As stated above, if your Magnum revision number is lower than ‘REV 7’ 

proceed to step #4.

4.  Turn the replacement keypad over to the board side.

5.  Remove the lexan cover, locate the four white plastic nuts, remove these 

and the lexan cover can be removed by lifting up on all sides.

6. 

There are two jumper pins,  as shown in figure 2, that need to be moved as 

shown.

 

The pins are factory set for +12VDC, they must be changed to +5VDC.

7.  Move both jumpers to the 5VDC pins for MAGNUM’S older than REV ‘7’. 

8.  Replace the lexan cover, and you can now install your replacement keypad.

9.  Your replacement keypad comes with an RS232 port and an MCS-RS232 EXTENDER which can be 

mounted to the front of your enclosure so that the enclosure door can remain closed when using the 
RS232 port.

 

If you do not require the MCS-RS232 EXTENDER, set this part aside.

IMPORTANT

1

FIGURE 1- MAGNUM

FIGURE 2

Keypad replacement

(Pins factory set for Magnum

Revision 7 or higher, +12 VDC)

2

KIT CONTAINS

MAG-KEYPAD-OEM-232

MAG-KEYPAD CABLE

MCS-RS232-EXTENDER

PROPER WIRING FOR KEYPAD ON 

REVERSE SIDE OF THIS SHEET

MAG-KEYPAD-OEM-232-KIT

For MCS-PANEL or MCS-DOOR

Отзывы: