background image

 

 

 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

NetworX

TM

 Series 

 

NX-1348E-ICON Icon keypad 

  

 

User manual 

 
 
 
 
 
 
 

g

GE Interlogix  

Summary of Contents for NX-1348E-ICON

Page 1: ...NetworXTM Series NX 1348E ICON Icon keypad User manual g GE Interlogix ...

Page 2: ... 10 CHANGING MODES WHILE SYSTEM ARMED 10 DISARMING THE SYSTEM 10 CANCEL ABORT FEATURE OPTIONAL 10 BYPASSING ZONES 10 GROUP BYPASS 11 UNBYPASSING ZONES 11 TURNING THE DOOR CHIME ON AND OFF 11 ADDING AND CHANGING USER CODES 12 ASSIGNING USER CODE AUTHORITY LEVELS 13 OTHER KEYPAD FUNCTIONS 14 SETTING THE KEYPAD TONE 14 CHANGE PARTITION OPTIONAL 14 VIEW ALARM MEMORY 14 TEST FUNCTION OPTIONAL 14 RESET ...

Page 3: ...and sounds mean will help you easily operate your system Keep in mind the level of security you will obtain with this system relates specifically with two major factors 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system You should be aware of the ...

Page 4: ...en A system that is ready to be force armed will flash the ready icon Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zones with a single operation Instant Delay An option that allows an instan...

Page 5: ...enter an emergency report could be sent to that center Auxiliary Emergency Key This key can activate the auxiliary alarm when pressed for two seconds If your system is connected to a monitoring center an emergency report could be sent to that center Police Panic Hold Up Key This key can sound a local audible alarm when pressed for two seconds If your system is connected to a monitoring center an e...

Page 6: ...icon is on when the system is armed The armed icon is off when it is disarmed The armed icon will flash when there has been an alarm during the previous arm cycle FIRE ICON A steady fire icon means a fire zone has been faulted A rapidly flashing fire icon means that a fire zone is in a trouble condition ...

Page 7: ...tion READY ICON The ready icon is on when the system is ready to arm and flashes if ready to force arm NOT READY ICON The not ready icon is on when the system is not ready to arm because of a zone s being faulted ALARM ICON The alarm icon is flashing when an alarm has occurred SILENCED ICON The silenced icon appears after a code has been entered to silence the siren but the zone has not been clear...

Page 8: ... the exit delay as a warning that the time is running out The user may want to disarm the system if the exit led is flashing in order to prevent an alarm The user may then re arm the system and exit before the delay expires BYPASS LED The bypass led is on when any zone in this keypad s partition is bypassed The zone s that is bypassed will also be illuminated If the bypass led is off no zones are ...

Page 9: ... secure NOTE If any zones are bypassed a sensor in that zone can be violated without affecting the ready icon The security system will not arm if the not ready icon is on or flashing If the power icon is off you have no AC power Restore power if possible If not contact your installing company for service Step 2 Enter your 4 or 6 digit user code If Auto Bypass is enabled all interior zones will be ...

Page 10: ...SARMED If a valid code is not entered before the end of the entry delay an alarm will occur NOTE If the armed icon is flashing during the entry delay the alarm system has been activated in your absence Leave the building immediately and call your alarm company and or the police from a safe location CANCEL ABORT feature optional The cancel led will flash during an abort delay time If a code is ente...

Page 11: ...ocedure on a zone that is already bypassed The corresponding icon for that zone will go off when unbypassed NOTE All zones will automatically be unbypassed each time the system is disarmed Turning the door chime ON and OFF The door chime is turned on or off by pressing the CHIME key while the system is in the disarmed state If the chime is on the chime led will be illuminated If the chime is off t...

Page 12: ...cons will illuminate specifying the first digit of the user code When all icons are all illuminated code is blank when all icons are off 0 Use the and keys to view the next digit or enter new 4 or 6 digit user code While using the and keys you can change any digit by entering a new digit This will advance you to the next digit To delete a user code enter r r r r for a 4 digit code or r r r r r r f...

Page 13: ... Reporting 8 If this icon is on this code is programmed as a function code Do not change Press to exit Step 5 Press the r key The ready led is on constant and instant icon is on constant This moves you to the partition enable The user has access in partitions that are illuminated Step 6 The illuminated numbers indicate each partition where the user has access To change any of the partitions where ...

Page 14: ...along with the alarm icon flashing on the keypad Step 2 The ALARM MEMORY feature will flash those zones that created alarms and will display steady those zones that were bypassed during the last alarm Test function optional If programmed this function will perform a battery test communicator test and or a siren test Alarms and reports will not be sent unless a communicator test is performed at whi...

Page 15: ...1 Press r 9 7 Enter Code icon will appear Step 2 Enter a Master Code Then the service icon will begin to flash Step 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the following table Step 4 Enter the minutes code which must be two 2 digits Then the ready icon will come on constant Example 7 minutes after would be entered 0 7 12 00 Midnight 00 8 00 AM 08...

Page 16: ...of 8 service icons 2 RESERVED 3 ZONE LOW BATTERY Press the 3 key The zone icon s will illuminate showing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service icons 4 ZONE LOSS OF SUPERVISION Press the 4 key and the zone icon s will illuminate showing which zone s has loss of supervision This only applies to wireless zones Press key to ret...

Page 17: ... of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s are bypassed Pulses when the armed status changes and a low battery is detected Pulses when the armed status changes and a Tamper condition is detected Beeps to indicate Telephone Line Cut if selected Pulses when one or more of the following conditions are detected Zo...

Page 18: ...________________ This system is is not partitioned EMERGENCY ACTIVATION KEYS check if enabled Fire Auxiliary Emergency Police PROGRAMMED FUNCTIONS Abort Delay Cancel Alarm Forced Arming Auto Bypass Change Partitions Group Bypass Auto Instant Chime Quick Arm Battery Test Communicator Test Re Exit Siren Test ENTRY EXIT DELAY TIMES Exit Delay Time __________ Secondary Exit Delay Time ________ Entry D...

Page 19: ...______________________ 35 _________________________ 12 _________________________ 36 _________________________ 13 _________________________ 37 _________________________ 14 _________________________ 38 _________________________ 15 _________________________ 39 _________________________ 16 _________________________ 40 _________________________ 17 _________________________ 41 _________________________ ...

Page 20: ...s a division of GE Interlogix N V COPYRIGHT 2003 GE Interlogix N V All rights reserved GE Interlogix N V grants the right to reprint this manual for internal use only GE Interlogix N V reserves the right to change information without notice ...