when clearing the settings for an EventSensor in the EventSensor Setup menu. If there is no response within
30 seconds, the T830 will cancel the command. Default is ON.
Time Stamp Format
toggles through three options for how time stamps are formatted: HH:MM, HH:MM:SS,
or Blank. Default setting is HH:MM.
Date Stamp Format
toggles through four options for how date stamps are formatted: MM/DD, MM/DD/YY,
MM/DD/YYYY, or Blank. Default setting is MM/DD.
Space After Date/Time Stamp
is an ON/OFF toggle to set whether a space is appended to the end of the
Date/Time stamp. Default setting is ON.
Prompt
The Prompt option sets the character(s) or settings values displayed as the command line prompt. The
prompt characters can be customized, and includes the ability to embed one or more settings values in the
prompt, for example the site name could be used in the prompt using a settings key of
sys.sitename
. A
customized command prompt can help simplify administration of units, particularly where multiple units are
involved.
The Prompt can be set as plain text characters or if using a settings key the syntax is:
$(setting_key_name)
.
If the setting key is not accessible for any reason (invalid key, insufficient user access level, etc.), "ERROR" is
displayed instead.
The setting can contain up to 64 characters, but the prompt itself is limited to 30 characters.
This selection displays the System Date/Time menu where you can manage the clock, daylight savings
control, and configure a networked time server.
This option displays a menu for configuring legacy products that may be connected to the TeleBoss.
Joinable Pass-through
This is and ON/OFF toggle to allow or disallow multiple user pass-through sessions. ON allows more than
one user to connect on a pass-through session. OFF does not allow more than one concurrent pass-through
sess
ion, and those attempting to join after the first user is connected will receive a “port in use” error
message. Default setting is ON.
General Settings as accessed via the Web UI
The general settings options, where you can set the site name, answer string, confirmation prompt, date/time,
and other general settings, can also be set from the Web Interface. They are located under the General tab
on the left hand menu under General System.