from the Event Log Settings and Audit Log Settings menus per the parameters set there. If the unit has
additional serial ports via an expansion card, a FILE location will be available for each port.
The number of records stored in each these four files can be displayed using the
DIR
command on any
connection to the command interface. To view the data in a FILE, type:
ACCESS[file number]
and enter.
PRT
and enter, to set a partition at this point in the data file.
RL
and enter.
RL
releases all data in the partition;
RL
plus a number would release just that number of records;
RL@
a
number release all records beginning at the specified record number;
RLn@nnn
release
n
number of records
beginning at record number
nnn
.
To delete the records that have been so released type
CLEAR
.
CLEAR
deletes all the records released via
one of the RL commands. Records not released are not deleted.
Serial Monitoring (Data Events)
The TeleBoss can be used to monitor incoming data for user-defined strings and then report the event via
several avenues. The T830 allows for up to 200 different data events. Each data event contains independent
actions, counters, and other unique settings. Data events triggered within the T830 can be logged to an Event
Log. This file can be viewed through the Event Log section of the Setup menu, via the
TYPE EVENTS
command, or via FTP or the web interface.
Environmental Monitoring
Through the use of external EventSensor modules and/or internal Expansion Cards, a variety of
environmental sensor monitoring and alarming capabilities are available in the TeleBoss. Each individual
sensor can be configured with independent actions, counters and other unique settings. Using optional
sensors the TeleBoss can monitor temperature, humidity, air-flow, water on site, smoke and carbon monoxide,
as well as DC or AC power and battery conditions. Sensor events triggered within the T830 can be logged to
an Event Log. This file can be viewed through the Event Log section on the Setup menu, via the
TYPE
EVENTS
command, or via FTP or the web interface.
Features and Accessories
Standard Equipment
The base T830 comes with the following standard on-board equipment:
AC power input
32MB logging database for text records
(2) RJ45 DTE serial I/O ports
(1) RJ45 Sensor port for connection of Asentria EventSensors
(2) 10/100Mb Ethernet interfaces with support for six 802.1Q VLAN interfaces on each
(1) MMC memory I/O slot
(0, 2 or 6) Expansion Card slots