![Asentria TeleBoss 830 Скачать руководство пользователя страница 120](http://html.mh-extra.com/html/asentria/teleboss-830/teleboss-830_user-manual_2981744120.webp)
TeleBoss 830 2.11.370 STD User Manual
Page 120
Numeric Message
This is the series of digits (typically callback number) sent to a numeric pager.
Post Callout Delay
This is the number of seconds the unit will wait before sending the pager ID. The default setting is 15
seconds.
Post ID Delay
This is used to set the number of seconds the unit will wait before sending any message data. The default
setting is 5 seconds.
Pager n Settings as accessed via Web UI
The same pager settings are located at the bottom of the Actions Settings page. They would be accessed by
selecting Events on the left hand menu and the choosing General Actions. Use the drop down options in the
grey Pager header box for additonal pagers.
Post ID Delay
sets the number of seconds (0 to 255) the unit will wait before sending any message data.
Default setting is 5 seconds.
Action Settings
This menu is used to configure various general action parameters, such as action schedules and event
reminder intervals
TeleBoss 830 - Action Settings
A) Callout Attempts [5]
B) Callout Delay (seconds) [60]
C) Action Schedule [OFF]
D) Reminder Interval (minutes) [120]
E) Asentria Alarm Version [1.1]
F) Require Asentria Alarm ACKs [OFF]
Callout Attempts
This option is used to set the total number of times to attempt dispatch, Malert or modem callouts if previous
attempts fail. The default setting is 5.