Fail Threshold
This field sets how many ping checks in a row must fail before the modem or TeleBoss is power cycled.
Range is 2 to 50, default is 5.
RX Reset
This check box is an on/off setting that determines whether the connectivity check trigger is inhibited if any
data is received on the wireless interface. The default is ON (checked).
Wireless Modem Settings as accessed via Web UI
The Wireless Modem settings are accessed in the Web Interface using the Communication option on the left
hand menu and then select Wireless Modem.
The upper section of the Wireless Modem Web Page is a Status Page for the Wireless Modem. The
information will be filled in based on the type of modem installed. For that reason, the status information
section will vary. This section displays information such as if the modem is connected with the wireless
network, Signal Strength, the IP Address of the modem along with basic information on the modem itself and
any installed SIM. This would be the same sort of information that you can access using the
?W INFO
from
the command line interface.
The lower section cover the settings available to configure your wireless modem. These are the same
settings as covered above.