Chapter 2 Alarm
2.
The upstream signals sent to NR8250 equipment contains the HP-RDI signal.
3.
The RTUB board that reports the alarm is faulty.
Handling Procedure
1.
Check whether NR8250 uplink equipment reports alarms such as HP-UNEQ (alarm
code: 134237748), HP-TIM (alarm code: 134237751), or AU-AIS (alarm code:
134237929).
l
If yes, handle the alarm accordingly.
l
If no, go to step 2.
2.
Ensure that the signals sent by upstream equipment to NR8250 equipment do not
contain the HP-RDI signal.
3.
The alarm is caused by RTUB board failure. Replace the board.
2.2.23 134237929 AU-AIS
Alarm Property
l
Alarm Code: 134237929
l
Alarm Information: Every bit in the AU structure including AU-PTR is 1.
l
Alarm Level: Critical
l
Alarm Type: Communications Alarm
Sub-code Description
l
Sub-code 1: STM-1 of optical port 1 (LMT displays "STM-1");
l
Sub-code 5: Path 1 of optical port 2 (LMT displays "STM-4-Channel1");
l
Sub-code 6: Path 2 of optical port 2 (LMT displays "STM-4-Channel2");
l
Sub-code 7: Path 3 of optical port 2 (LMT displays "STM-4-Channel3");
l
Sub-code 8: Path 4 of optical port 2 (LMT displays "STM-4-Channel4");
l
Sub-code 10: STM-1 of optical port 2 (LMT displays "2STM-1").
Effect on the System
The receive signal transmitted on the SDH link is interrupted.
Possible Causes
1.
The upstream signals sent to NR8250 equipment contains the AU-AIS signal.
2.
The RTUB board that reports the alarm is faulty.
Handling Procedure
1.
Check whether NR8250 upstream equipment detects the AU-AIS signal.
l
If yes, troubleshoot the faulty device. Replace the RTUB board.
l
If no, go to step 2.
2.
The alarm is caused by RTUB board failure. Replace the board.
2-41
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential