ZXMW NR8250 Alarm and Notification Handling Reference
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: Optical port 1 on the RTUB board;
l
Sub-code 2: Optical port 2 on the RTUB board.
Effect on the System
The traffic at the port corresponding to the alarm is interrupted.
Possible Causes
1.
Optical module is disabled manually.
2.
The RTU board where optical module is located is faulty.
Handling Procedure
1.
Check whether the optical module is disabled.
l
If yes, select
TDM > Laser
and enable the optical module and the alarm is cleared.
l
If no, go to step 2.
2.
Replace the RTU board where the optical module is inserted.
2.1.15 134239932 ODU configuration mode invalid
Alarm Property
l
Alarm Code: 134239932
l
Alarm Information: The alarm is reported if ODU does not support the issued
configuration mode.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The traffic carried by the board is interrupted.
Possible Causes
1.
The ODU does not support the configuration of the corresponding mode.
2.
The ODU is faulty.
Handling Procedure
Replace the ODU.
2-12
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential