Chapter 2 Alarm
2.2.17 134237751 HP-TIM
Alarm Property
l
Alarm Code: 134237751
l
Alarm Information: The alarm is reported if higher-order path trace identification is
mismatched. This is detected by J1.
l
Alarm Level: Major
l
Alarm Type: Communications Alarm
Sub-code Description
l
Sub-code 1: STM-1 of optical port 1 (LMT displays "STM-1");
l
Sub-code 5: Path 1 of optical port 2 (LMT displays "STM-4-Channel1");
l
Sub-code 6: Path 2 of optical port 2 (LMT displays "STM-4-Channel2");
l
Sub-code 7: Path 3 of optical port 2 (LMT displays "STM-4-Channel3");
l
Sub-code 8: Path 4 of optical port 2 (LMT displays "STM-4-Channel4");
l
Sub-code 10: STM-1 of optical port 2 (LMT displays "2STM-1").
Effect on the System
The carried services are affected..
Possible Causes
1.
The J1 byte received by the NR8250 is inconsistent with that sent by the upstream
equipment.
2.
The RTUB board that reports the alarm is faulty.
Handling Procedure
1.
Check whether the transmission value of
VC-4 path access point identifier (J1 byte)
of the upstream equipment and the J1 expectation value of the local equipment are
both
-ZTE-MW-NR8250-
.
l
If yes, go to step 2.
l
If no, modify the two as
-ZTE-MW-NR8250-
.
2.
The fault is caused by RTUB board failure. Replace the board.