Chapter 2 Alarm
l
If yes, disable the loopback function after the test or maintenance is completed.
(Path:
Maintenance > Radio Port
).
l
If no, go to step 2.
2.
Replace the RMU board.
2.1.24 134237782 SNCP route setting alarm
Alarm Property
l
Alarm Code: 134237782
l
Alarm Information: The alarm is reported if the SNCP route setting fails.
l
Alarm Level: Major
l
Alarm Type: Equipment Alarm
Sub-code Description
None.
Effect on the System
The services using this route are interrupted.
Possible Causes
The system fails to configure the SNCP route.
Handling Procedure
Invalidate the route again.
2.1.25 9001 AC input Switch Off
Alarm Property
l
Alarm Code: 9001
l
Alarm Information: AC input switch is off
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
1.
The rectifier fails to work normally, only the battery can work.
2.
When the battery runs out, the base station is powered down.
2-19
SJ-20111008094748-008|2012–05–30 (R1.1)