Chapter 2
Alarm
Table of Contents
2.1 Equipment Alarm
2.1.1 1001 Board powered off
Alarm Property
l
Alarm Code: 1001
l
Alarm Information: The board is powered off.
l
Alarm Level: Major
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: Management power
l
Sub-code 2: Service power
Effect on the System
The board's communication link is broken, and services carried by the board are
interrupted.
Possible Causes
The board is powered off.
Handling Procedure
1.
Check the additional information of the alarm.
If the alarm has additional information, check whether the inserted board of the NE is
inconsistent with that configured at OMCB.
The following lists the board types (X represents a hexadecimal number 0 ~ F):
2-1
SJ-20111008094748-008|2012–05–30 (R1.1)
ZTE Proprietary and Confidential