Chapter 2 Alarm
l
Sub-code 3: Failed to load DSP software
l
Sub-code 4: Failed to download CPU software
l
Sub-code 5: Failed to download FPGA software
l
Sub-code 6: Failed to download DSP software
Effect on the System
The services carried by the board are interrupted.
Possible Causes
1.
The board's software version, which is saved in the main control board, is incorrect.
2.
The board is faulty.
Handling Procedure
1.
In the software version management window, select
Maintenance > Version > IDU
and check whether the software version is correct.
l
If no, download the correct version package.
l
If yes, go to step 2.
2.
Replace the board.
2.3.8 6206 Running software version fault
Alarm Property
l
Alarm Code: 6206
l
Alarm Information: When the main control board detects that the running software
version does not exist, this alarm is reported.
l
Alarm Level: Major
l
Alarm Type: Handling Alarm
Sub-code Description
l
3145728: RCUA CPU version
l
3147776: RCUA FPGA version
l
9503265: RTUA CPU version or RTUB CPU version
l
9505280: RTUA FPGA version
l
9503424: RTUM CPU version
l
9505296: RTUB FPGA version (FUNC=0)
l
9505297: RTUB FPGA version (FUNC=1)
l
9568784: RMU CPU version
l
9570832: RMU FPGA version
l
9597456: RMU CFG version
Effect on the System
l
The board cannot obtain the software, and cannot start properly after being reset.
2-65
SJ-20111008094748-008|2012–05–30 (R1.1)